19
Level II Programming – P Values
Level II program parameters can be adjusted and used to fine-tune the conditioner’s operation. The parameters are accessible by
pressing and holding the UP and DOWN buttons until the control displays a “P” value. Note: The control must be in the home position to
change settings. See Table below for Level ll parameters. Typically the Level ll parameters will not need to be adjusted, as the default
settings accommodate most applications. Contact your Water Treatment Professional before attempting any programming.
P#
Description
Range
Minimum
Increments
Default
Units
Notes
P1
Time of Day
12 Hr
24 Hr
1 Min
12:00PM
Hr./Min.
Range dependent on P10 setting
P2
Day of Week
Sun-Sat
1 Day
Sun
Days
Set to actual day of the week
P3
Time of Regen
12 Hr
24 Hr
1 Min
12:00PM
Hr./Min.
Range dependent on P10 setting
P4
Day Override
0-30
1 Day
0
Days
0 = Disabled
P5
Not Used
P6
Salt Setting
3-18
50-290
1
10
9
110
Lbs/Cu ft
3
g/L
Set in Level I Programming
P7
Capacity
(View Only)
1-140
0.1-14.0
1
0.1
Calculated
Kilograins
Kilograms
Values dependent on P9 setting
P8
Not Used
P9
Units of Measure
0-1
1
0
0 = US 1 = Metric
P10 Clock Mode
0-1
1
0
0 = 12 Hr 1 = 24 Hr
P11 Service Interval
0-99
1
0
Months
0 = Disabled 30 Day Month
P12
Minimum
Days Between
Regeneration
0-14
1
0
Days
P13 Low Salt Sensitivity
0-2
1
2
0 = Highest Sensitivity
1 = Mid Sensitivity
2 = Lowest Sensitivity
3 = Turn Off Check Salt Light Function
P14 Disable Probes
0-1
1
0
0 = Normal Operation
1 = Probes Disabled; No Err6
Programming the Lockout Feature
All parameters can be locked out when the control is in Level ll programming.
Simply press the REGEN button during Level ll programming and a Lock icon
will appear indicating that the specific setting has been locked out. When locked
out, the setting cannot be adjusted. To disable the Lock Out Feature, press the
REGEN button when in Level ll. The lock icon will not be displayed.
Time/Day
Regeneration Time/Day
Salt Amount
SU MO TU WE TH FR SA DAYS
PM
Capacity
Check Salt