46
Chapter 2
www.aerotech.com
2.3.5. End Of Travel Limit Input Interface (J207)
End of Travel (EOT) limits are used to define the end of physical travel. The EOT limit inputs accept 5-24
VDC level signals. The active state of the EOT limits is software selectable by the EndOfTravelLimitSetup
axis parameter (refer to the Ensemble Help file). Limit directions are relative to the encoder polarity in the
diagnostics display (refer to
).
Positive motion is stopped by the clockwise (CW) end of travel limit input. Negative motion is stopped by the
counterclockwise (CCW) end of travel limit input. The Home Limit switch can be parameter configured for
use during the home cycle, however, the CW or CCW EOT limit is typically used instead.
Opto-isolated user inputs 0-3 can also be used as the end-of-travel limit inputs, see
Figure 2-21:
End of Travel Limit Input Connections
Table 2-17:
End of Travel Limit Input Pins on the Motor Feedback Connector (J207)
Pin#
Description
In/Out/Bi
12
Clockwise End of Travel Limit
Input
16
+5V Power for Limit Switches (500 mA max)
Output
20
Signal Common for Limit Switches
N/A
22
Home Switch Input
Input
24
Counterclockwise End of Travel Limit
Input
Ensemble HLe
Installation and Configuration
Summary of Contents for Ensemble HLe
Page 1: ...Revision 4 09 00 Ensemble HLe Hardware Manual ...
Page 14: ...Ensemble HLe Quick Installation Guide 14 www aerotech com This page intentionally left blank ...
Page 87: ... IO Expansion Board Ensemble HLe Figure 3 15 J302 J303 www aerotech com Chapter 3 87 ...
Page 98: ...98 Chapter 5 www aerotech com Ensemble HLe Accessories This page intentionally left blank ...