Installation and Configuration
Ensemble HLe
2.4.1. Typical ESTOP Interface
The user can connect an external emergency stop relay circuit to the Ensemble HLe’s motor power supply
input. This will remove power to the motor while maintaining control power, as shown in the
The external relay must be sized based on the number of the Ensemble HLes connected and the peak
current rating of each drive.
Figure 2-25:
Typical Emergency Stop Circuit
Table 2-21:
Typical ESTOP Relay Ratings
Axes
AC1
AC3
Aerotech P/N
Third Party P/N
1
32
16
ECW1018
Sprecher & Schuh CA7-16C-xx-xxx
2 to 5
85
43
ECW1019
Sprecher & Schuh CA7-43C-xx-xxx