1.1. Environmental Specifications
WARNING
:
General Hazard Warning!
Do not expose this product to environments or
conditions outside of the listed specifications. You could damage the equipment if you
exceed the environmental or operating specifications.
DANGER
:
Risk of Explosive Atmosphere!
l
Standard Aerotech stage/motors are not rated for applications with explosive
atmospheres such as air-born dust or combustible vapors.
l
Do not operate stage/motors outside of Aerotech environmental specifications.
Table 1-2:
Environmental Specifications
Ambient
Temperature
Operating: 10° to 35° C (50° to 95° F)
The optimal operating temperature is 20° C ±2° C (68° F ±4° F). If at any time the
operating temperature deviates from 20° C degradation in performance could
occur.
Storage: 0° to 40° C (32° to 104° F) in original shipping packaging
Humidity
Operating: 20% to 60% RH
Storage: 10% to 70% RH, non-condensing in original packaging.
The stage should be packaged with desiccant if it is to be stored for an extended
time.
Altitude
Operating: 0 m to 2,000 m (0 ft to 6,562 ft) above sea level
Contact Aerotech if your specific application involves use above 2,000 m or below
sea level.
Vibration
Use the system in a low vibration environment. Floor or acoustical vibration can
affect system performance. Contact Aerotech for information regarding your
specific application.
Protection
Rating
These stages have an ingress protection rating of IP10.
Use
Indoor use only
1.2. Accuracy and Temperature Effects
Aerotech products are designed for and built in a 20°C (68°F) environment. Temperature changes
could cause a decrease in performance or permanent damage to the stage. At a minimum, the
environmental temperature must be controlled to within 0.25ºC per 24 hours to ensure the stage
specifications are repeatable over an extended period of time. The severity of temperature effects
on all specifications depends on many different environmental conditions, which include how the
stage is mounted. Contact the factory for more details.
The accuracy specification of stage is measured 25 mm above the table with the stage in an
unloaded condition. The stage is assumed to be fully supported by a mounting surface meeting or
exceeding the specification in
The accuracy of the screw is a key element in the overall positioning accuracy of the SL stage. A scale
error can be expected if temperature of the screw differs from 20° C (68° F). The greater the
temperature difference, the greater the error. The temperature of the screw depends on the speed
and duty cycle of the stage. The faster the movement and higher the duty cycle, the more the stage
accuracy will be affected by heat. The thermal expansion coefficient of the screw is 11.7 ppm/°C.
ECO165SL Hardware Manual
1.1. Environmental Specifications
www.aerotech.com
17