4.3. Motor Mounting
DANGER
:
Electrical Shock Hazard!
l
Do not connect or disconnect electrical components, wires, and cables while this
product is connected to a power source.
l
Before you do maintenance to the equipment, disconnect the electrical power.
l
Uncouple or otherwise prevent motion of motor-coupled machinery when you do ser-
vice to the equipment.
Table 4-1:
Hardware Requirements
Motor
Screw Size
Shaft Coupling Screw
Size
Coupling Screw Bit Size
Coupling Screw Torque
M4
M2.5
2 mm Hex
7 in·lbs
IMPORTANT
: Use Loctite 242 or Loctite 248 on the motor and coupling adapter
hardware (
). Loctite products are printed with an expiration date. Before use,
be sure that the expiration date is legible and the product has not expired.
If your stage is used in a vacuum or cleanroom environment, contact Aerotech.
Figure 4-3:
Motor Mounting Overview
4.3. Motor Mounting
ECO165SL Hardware Manual
48
www.aerotech.com