1.1. Environmental Specifications
WARNING
:
General Hazard Warning!
Do not expose this product to environments or
conditions outside of the listed specifications. You could damage the equipment if you
exceed the environmental or operating specifications.
DANGER
:
Risk of Explosive Atmosphere!
l
Standard Aerotech stage/motors are not rated for applications with explosive
atmospheres such as airborne dust or combustible vapors.
l
Do not operate stage/motors outside of Aerotech environmental specifications.
Table 1-2:
Environmental Specifications
Ambient
Temperature
Operating: 10° to 35° C (50° to 95° F)
The optimal operating temperature is 20° C ±2° C (68° F ±4° F). If at any time the
operating temperature deviates from 20° C degradation in performance could
occur.
Storage: 0° to 40° C (32° to 104° F) in original shipping packaging
Humidity
Operating: 20% to 60% RH
Storage: 10% to 70% RH, non-condensing in original packaging.
The stage should be packaged with desiccant if it is to be stored for an extended
time.
Altitude
Operating: 0 m to 2,000 m (0 ft to 6,562 ft) above sea level
Contact Aerotech if your specific application involves use above 2,000 m or below
sea level.
Vibration
Use the system in a low vibration environment. Floor or acoustical vibration can
affect system performance. Contact Aerotech for information regarding your
specific application.
Protection
Rating
These stages are not suited for dusty or wet environments. This equates to an
ingress protection rating of IP30.
Use
Indoor use only
1.2. Accuracy and Temperature Effects
Aerotech products are designed for and built in a 20°C (68°F) environment. Temperature changes
could cause a decrease in performance or permanent damage to the stage. At a minimum, the
environmental temperature must be controlled to within 0.25ºC per 24 hours to ensure the stage
specifications are repeatable over an extended period of time. The severity of temperature effects
on all specifications depends on many different environmental conditions, which include how the
stage is mounted. Contact the factory for more details.
The accuracy specification of stage is measured 25 mm above the table with the stage in an
unloaded condition. The stage is assumed to be fully supported by a mounting surface meeting or
exceeding the specification in
APR100DR
Hardware Manual
16
www.aerotech.com
Summary of Contents for APR100DR Series
Page 1: ...Revision 2 00 APR100DR High Precision Mechanical Bearing Rotary Stage HARDWARE MANUAL...
Page 21: ...Figure 2 2 APR100DR Stage Mounting Holes Hardware Manual APR100DR www aerotech com 21...
Page 23: ...Figure 2 3 Cantilevered Load Capabilities Hardware Manual APR100DR www aerotech com 23...
Page 24: ...This page intentionally left blank APR100DR Hardware Manual 24 www aerotech com...
Page 32: ...Figure 3 3 APR100DR Motor and Feedback Wiring E4 APR100DR Hardware Manual 32 www aerotech com...
Page 40: ...This page intentionally left blank APR100DR Hardware Manual 40 www aerotech com...
Page 44: ...Figure 4 1 APR100DR Limit Flag Adjustment APR100DR Hardware Manual 44 www aerotech com...
Page 52: ...This page intentionally left blank APR100DR Hardware Manual 52 www aerotech com...