TECHNICAL SPECIFICATIONS
Page 31 of 32
10 Technical specifications
Many different components installed in an air dehumidifier decide
on its dehumidifying performance.
Since these components can never be completely identical the
actual performance according to DIN EN 810 may deviate by up to
5% from the specified performance.
General data
Power supply
230 V / 50 Hz
Protection class
IP X4
Protection for indoor
swimming pools
RCCB to be installed by user
Operating conditions
+ 3 °C to + 32 °C
40% r. h. to 95% r. h.
Type
Unit
AD 420
AD 430
Air circulation rate
Fan speed I
cbm / h
300
500
Fan speed II
cbm / h
390
625
Power consumption
watt max.
450
600
Noise level
dB (A)
46
51
Dimensions H x W x D
mm
524 / 320 / 360
578 / 329 / 380
Weight
kg
14
21
Refrigerant (for filling quantity refer to
type plate)
R134a
R407c
Dehumidifying performance / power consumption at:
30 °C / 80% r. h.
l / 24 h
19
34
watt
420
530
27 °C / 60% r. h.
l / 24 h
11
22
watt
360
430
20 °C / 60% r. h.
l / 24 h
8
16,6
watt
340
390
10 °C / 70% r. h.
l / 24 h
6
11,4
watt
280
330