SAFETY 

 

 

 

 

Page 6 of 32 

Safety instructions 

The air dehumidifiers must 

not

 be used under the following conditions: 

 

In rooms with potentially explosive atmospheres. 

 

In rooms with aggressive atmospheres, e.g. ammonia, wood acids, 

chemicals, excessive chlorine content etc. 

 

In rooms with water with a pH value outside the range from 7.0 to 7.4. 

 

In case of lower pH values there is risk of corrosion for all metals 

and risk of damage to mortar-containing materials (joints). Higher 

pH values cause skin and mucous membrane irritations and 

increased lime deposits. 

 

 

In rooms with salt or liquids with a salt content > 1%  
(incl. brine baths). 

 

In rooms with ozone-treated air. 

 

In rooms with high solvent concentration. 

 

In rooms with extreme dust load. 

 

Please note that excessive air movements in the room may impair 

the function of the air dehumidifier because they could disturb the 

air flow of the dehumidifier. 

 

In addition the following must be observed when using the air dehumidifier: 

 

Work on electrical equipment may only be carried out by skilled electricians. 

 

Original spare parts or spare parts approved by the manufacturer shall 

exclusively be used. 

 

In the event of any malfunction the air dehumidifier must be switched off and 

secured against unintended restarting. 

 

Summary of Contents for AD 420

Page 1: ...MADE IN GERMANY AD 420 430 11 2013 Rev 3 EN INSTRUCTION MANUAL Air Dehumidifier Series AD 420 AD 430...

Page 2: ......

Page 3: ...hts reserved The instruction manual is based on the technical and product specific parameters The manufacturer reserves the right to add supplementary information to the instruction manual Any use of...

Page 4: ...___ 10 Pump out kit for condensate___________________________________ 10 Method of operation _________________________________________ 11 5 Transport and installation _________________________________...

Page 5: ...________________________________________ 29 Storage ___________________________________________________ 29 Disposal __________________________________________________ 30 10 Technical specifications __...

Page 6: ...keep this instruction manual in a safe place In the section below you will find information about the target groups of this instruction manual and the conventions used in this document Target groups T...

Page 7: ...occurs are described in this way WARNING Type and source of hazard This symbol in connection with the word Warning warns of a risk involving severe injury Measures to avert danger or immediate measure...

Page 8: ...ories Waste water hoses and air filters must be properly installed and must not disable the protection devices of the condensation dryers The operating elements must always be accessible Authorised op...

Page 9: ...increased lime deposits In rooms with salt or liquids with a salt content 1 incl brine baths In rooms with ozone treated air In rooms with high solvent concentration In rooms with extreme dust load P...

Page 10: ...limits of designated use also involves observing the specified operating conditions refer to page 15 Any use of the air dehumidifier not in conformity with or going beyond the designated use is consid...

Page 11: ...ally a wall bracket is available for stationary attachment to a wall Fig 1 AD 420 430 series air dehumidifier isometric view 1 Carrying handle 4 Operating panel 2 Front wall air outlet 5 Ventilation p...

Page 12: ...intake area with air filter 5 AMP connector for connecting a pump out kit with dummy plug for operation without pump 3 Condensate drain pipe for condensate drain hose The water collecting tank is loca...

Page 13: ...AD 420 430 air dehumidifiers can be equipped with a pump out kit Ask your AERIAL dealer for the pump out kit It can be installed in just a few steps and can be removed just as quickly too Fig 3 Pump...

Page 14: ...principle of condensation with heat recovery The fan Fig 4 item 4 draws the moist air in through a cooling coil evaporator Fig 4 item 2 In the cooling coil the air is cooled so far below the dew point...

Page 15: ...ipping CAUTION Material damage Pulling the power cable may damage the cable Always disconnect the mains plug from the socket outlet before transport Always use the carrying handles to transport the ai...

Page 16: ...ording to the local regulations 3 Check the delivery refer to page 7 for completeness 4 Should any transport damage be detected after unpacking of the air dehumidifier or should the delivery be incomp...

Page 17: ...ce due to improper operating conditions improper installation Ensure that the wall is suitable for attachment of the wall bracket and can carry the weight of the air dehumidifier Attach the air dehumi...

Page 18: ...ons can result in damage problems in case of immediate switching on Therefore allow the air dehumidifier to adjust to the temperature before switching it on The suitable location for the air dehumidif...

Page 19: ...of installation The following items must be checked prior to electrical connection of the air dehumidifier Is the mains voltage in conformity with the voltage of the air dehumidifier Are socket and su...

Page 20: ...metre Do not immerse the hose end in water water back up may occur Never bend the hose Do not place any objects on the hose Check regularly whether condensate is properly discharged 1 Remove the wate...

Page 21: ...r 4 Ensure that the turn lock has been turned fully to the left horizontal position The bottom rabbet of the pump out kit rear wall must engage in the bottom edge of the water tank compartment 5 Put t...

Page 22: ...xample before transport of the air dehumidifier We recommend to empty the pump whenever the air dehumidifier is to be transported because otherwise water may flow out when the device is tilted To remo...

Page 23: ...nditions or improper operation of the air dehumidifier may constitute a risk Read the instruction manual before commissioning the air dehumidifier Series AD 420 430 operating elements Fig 5 Series AD...

Page 24: ...sition 80 100 The air dehumidifier will switch off at a relative humidity of about 80 95 and switch on again when a humidity of 80 95 is exceeded Position 60 80 The air dehumidifier will switch off at...

Page 25: ...Fig 5 item 1 If the air dehumidifier has been correctly connected and the existing humidity is higher than the set humidity value the air dehumidifier will start to work Operator control 1 Select the...

Page 26: ...area of the evaporator It transmits the defrost signal to the DryLogic electronics which will determine the defrosting demand and automatically start the defrost cycle During the defrost cycle the co...

Page 27: ...cleaning with compressed air WARNING Danger of injury due to sharp edged lamellae Wear protective gloves during cleaning of the heat exchanger CAUTION Damage to the appliance Cleaning agents can caus...

Page 28: ...Visual inspection collecting tank drain pipe and connected hose if any 10 Clean casing on the outside with a moist cloth do not use any aggressive detergent 11 Insert new or cleaned filter Use only o...

Page 29: ...Air dehumidifier shows poor or no humidification performance The ambient humidity is lower than 40 r h or the ambient temperature is less than 3 C Under these conditions operation of the air dehumidi...

Page 30: ...he air dehumidifier on Air dehumidifier without power supply Have the power cable the plug connection any extension cable used the plug socket and the building fusing checked by an expert Connect the...

Page 31: ...onments The humidity set on the hygrostat is not achieved or the air dehumidifier does not automatically switch off Hygrostat set to a value 45 r h Depending on the ambient conditions your air dehumid...

Page 32: ...m dust Storage To store a single air dehumidifier we recommend to proceed as follows 1 Package the air dehumidifier using cardboard 2 Store the air dehumidifier in conformity with the specified operat...

Page 33: ...to leave the top side completely free This allows storage of another air dehumidifier of this type stacked on top of the lower unit Disposal Please do not dispose of this air dehumidifier with the do...

Page 34: ...on for indoor swimming pools RCCB to be installed by user Operating conditions 3 C to 32 C 40 r h to 95 r h Type Unit AD 420 AD 430 Air circulation rate Fan speed I cbm h 300 500 Fan speed II cbm h 39...

Page 35: ...430 The product described is an air dehumidifier ready for connection Applicable standards EN ISO 12100 Safety of Machinery EN 61 000 Electromagnetic Compatibility EMC EN 60 335 2 40 Safety of electri...

Page 36: ......

Page 37: ...aerial de Internet www aerial de Branch Switzerland T fernstrasse 20 CH 5405 Baden D ttwil Phone 0041 56 470 21 55 Telefax 56 470 21 57 E Mail info aerial ch Internet www aerial ch klima24 ch Branch...

Reviews: