15/28
TF6751_D
Aereco S.A.
5) In case it does not fall down freely, loosen the 3 nuts (see below) and realign the motor plate so that the couplig falls down
freely from the motor axis to the turbine axis.
6) Gradually, tighten the 3 nuts with a torque wrench to 7.5 Nm. Tightening must be done one by one per occurrence.