13
LEGEND (page
2 - 3
)
1
Safety cap
2
Handle for carriage
3
Drain faucet
4
Water refill hose
5
Water tank automatic water refill
6
Steam plug
7
Steam outlet
7a
Continuous steam intake
8
Water mains connection (LP02C RID)
9
Power cable
10
Main switch
11
Steam ready light
12
Power light
13
Out of water warning light
14
Pressure gauge
15
Steam adjustment knob
15a
Continuous steam adjustment knob
16
Hot water flow knob 90°
17
Steam gun/handle
17a
Steam handle 5 meters (AV05 DUAL)
18
Steam button
19
Hot water button
20
Pump sensors
21
Boiler vent hose (LP02C RID)
22
Safety valve
23
Triangular steam brush (LP01 RA)
24
Steam lance (LP01 RA, AV05)
25
Steam accessories connection (LP01 RA)
26
Nr. 2 extensions 420 mm (LP01 RA)
27
Steam hose with continuous steam outlet
connections (AV05 DUAL)
28
Steam squeegee (LP01 RA)
29
PVC brush for steam lance (LP01 RA, AV05)
30
Steam floor brush (LP01 RA)
INSTALLATION / ACTIVATION
CAUTION RISK OF BURNING
STEAM GENERATORS WITH AUTOMATIC REFILL “RA” (LP01, LP02 and AV05)
• Make sure that the drain cock
3
is closed and that the machine is off. • Insert water
into tank
5
. • The water introduced must not be distilled or demineralized otherwise
the water level control system will not work. • Immerse the water refill hose
4
in the
water tank, and make sure that the pump sensors
20
are completely immersed in
the water. • Reposition the tank in its housing (except for LP02S RA). • Connect the
steam plug
6
of the handle to the steam outlet
7
of the appliance (except for LP02
models that have the steam gun already connected). For the LP01 RA model, insert
the accessory available according to the work to be performed (page 3 e 14). • Plug
the power cord
9
into a suitable electrical socket.
STEAM GENERATORS WITH MANUAL REFILL “M” (LP02S and LP02C)
• It is very important to position the machine at least 1 meter from the sink. • Make sure
that the drain cock
3
is closed, the machine is switched off and disconnected from the
mains and that there is no pressure in the boiler (the needle of the pressure gauge
14
must point to “0”). Open the safety cap
1
and fill the boiler with water. • It is not necessary
to use distilled/demineralised water. • Close the safety cap
1
without tightening too much.
• Plug the power cable
9
into a suitable electrical socket.
STEAM GENERATORS CONNECTED TO THE “RID” WATER MAINS (LP02C RID)
The appliance must be connected to the water inlet
8
of the water supply. Make sure that
inlet
8
is clean and install a water filter between the machine inlet and the water supply.
Make sure that the water pressure arriving from the water supply is min 1 Bar and max 4
Bar pressure.