3 9
WWW.AEM-TEST.COM
[email protected] | Version # : 2.2
TestPro CV100
User Manual
TestPro’s Switch Detail feature helps network professionals
identify the switch name and model number to which
the TestPro is connected to. Information such as port
number, VLAN ID, IP address and much more are also
readily available, eliminating the need to manually
trace network cables, saving users time and effort when
troubleshooting network related issues.
v. Switch Detail
•
•
•
To initiate Switch Detail, select [Tools].
Select [Switch Detail].
Key in the appropriate value for [Switch Query TimeOut]
(default is set to 30 seconds). Increase the timeout when
the tester fails to detect the switch information. Select
the protocol to be used - [CDP], [LLDP] or both. Select
[Start Test].
•
•
Switch Detail commences.
Once the Switch Detail process is complete, the results
will be displayed.
TestPro can open a TCP connection with the selected
target to test for port availability, by doing a TCP Connect
test, using a 3-way handshake (SYN, SYN/ACK, ACK). The
Autotest will run three times before reporting the results.
vi. TCP Connect
•
•
•
Select [Tools].
Select [TCP Connect].
On the TCP Connect screen, key in the desired URL or
IP address to be tested in the [Domain Name] field.
Specify the port to be used and the timeout period.