TestPro allows testers to collaborate better by sharing
projects with ease. Project files can be transferred from
one TestPro unit to another, using a USB flash drive. They
can also be emailed to testers in other locations. This saves
them in having to recreate a project/use case from scratch.
To export project(s):
Power on the TestPro and insert a USB flash drive
(formatted as FAT32).
TestPro will detect the USB flash drive and open the
USB Menu.
Select [Export Project]. TestPro will copy the project files
from the tester to the USB flash drive.
A dialog box will confirm successful export.
•
•
•
•
vii: Import Project
To import a project from a USB flash drive to a TestPro
device:
Power on TestPro and insert a USB flash drive
containing the project.dat file.
A [USB] menu will come up.
Select [Import Project].
A dialog box comes up asking to confirm the project
import. Click Yes
[Project Imported from USB Reboot is required]
message will appear. Select to reboot the device.
•
•
•
•
•
2 Cable Certification Test
The TestPro CV100 platform features the most sophisticated RF
measurement engine available in any handheld tester. Capable
of supporting up to 3Ghz frequency range, and testing all mode
combination parameters (including TCL, ELTCTL, DC Resistance
Unbalance), the TestPro CV100 exceeds level 2G accuracy
specifications for copper certification testing.
Currently available adapters provide CAT5e to CAT8
certification. The capability of the TestPro CV100 platform
makes it ideal for Fiber and Coax certification as well.
a. Project & Profile
The TestPro CV100 supports customer workflows through
projects and profile descriptions. [Project] is an identifier of
the customer site/location, whereas [Profile] refers to specific
test configurations.
i: Create Project & Profile
Select [Project]/[Profile] on the home screen to create
or edit a project. Once a project is selected, subsequent
Autotest results will be saved there.
Select [Project Manager] to choose a project, create a
new project or to delete an existing project.
Select [Add] to create a new project.
•
•
•
Key in the project name and select [ ].
A dialog box will appear confirming the TEST PROJECT
to be used as a current project. Select [Yes] and TestPro
will show various profiles. Select a profile and Save.
•
•
[Certification] for Copper Cable Certification.
[Validation] for Multi-Gig and BASE-T tests.
[Network Validation] for Network Autotest.
[Copper 2 Pairs] for 2 pair Copper Cable Certification
a.
b.
c.
d.