Technical data
ARCO SDI-12
Id-No. 00.14582.070470
Range
Temperatures -40...+70 °C
of application:
Wind speed 0...55 m/s
0...100 % r. h.
Protocol:
SDI-12
Supply voltage:
Sensor 9...15 VDC · 4 mA at 12 VDC
Housing:
Seawater resistant aluminium
specially coated
IP 65 in vertical position of use
Dimensions:
See dimensioned drawing
Weight:
Approx. 1.7 kg
Parameter wind direction
Measuring range:
0...360°
Accuracy:
± 1 %
Resolution:
< 1°
Starting value:
0.3 m/s
Damping ratio:
0.5...0.6
Parameter wind speed
Measuring range:
0.3...55 m/s
Accuracy:
± 2 % FS at 0.3...55 m/s
Resolution:
< 0.1 m/s
Starting value:
0.3 m/s
Distance constant: 4 m
Accessories:
(
please order separately)
Sensor connection cable with plug connector M12, 4-pin
Length:
12 m
Id-No:
32.14567.060000
Sensor connection cable with plug connector M12, 4-pin
Length:
15 m
Id-No:
32.14567.060010
(Other lengths available on request.)
Options:
(9340) Visualisation and evaluation software
MeteoWare-CS-3 Basic
Id-No. 36.09340.000000
Standards
•
EMC/EMI: EN 60945
•
Low voltage guideline 73/23/EWG and VDE 0100
•
WMO No. 8
•
VDI 3786 part 2
•
SDI12, 1.4, 2017
9 Warranty
Please note the loss that unauthorised manipulation
of the system shall result in the loss of warranty and
non-liability. Changes to system components require
express written permission from LAMBRECHT meteo
GmbH. These activities must be performed by a qualified
technician.
The warranty does not cover:
1. Mechanical damage caused by external impacts (e. g.
icefall, rockfall, vandalism).
2. Impacts or damage caused by over-voltage or
electromagnetic fields which are beyond the standards
and specifications of the device.
3. Damage caused by improper handling, e. g. by using
the wrong tools, incorrect installation, incorrect electrical
installation (incorrect polarity) etc.
4. Damage caused by using the device outside the specified
operation conditions.
10 Disposal
LAMBRECHT meteo GmbH is listed and registered at the
Stiftung Elektro-Altgeräte Register ear under:
WEEE-Reg.-No. DE 45445814
In the category of monitoring and control instruments, device
type: "Monitoring and control instruments for exclusively com-
mercial use".
Within the EU
The device has to be disposed according
to the European Directives 2002/96/EC and
2003/108/EC (Waste Electrical and Elec-
tronic Equipment). Do not dispose the old
device in the household waste! For an
environmentally friendly recycling and dis-
posal of your old device, contact a certified
disposal company for electronic waste.
Outside the EU
Please follow the regulations in your country regarding the
appropriate disposal of waste electronic equipment.
14
LAMBRECHT meteo GmbH
Tel
+49-(0)551-4958-0
Friedländer Weg 65-67
Fax
+49-(0)551-4958-312
37085 Göttingen
E-Mail [email protected]
Germany
Internet www.lambrecht.net
14582_ARCO_SDI-12_b-de.indd 21.22