THE SOUND INDICATORS

THE SYSTEM CONTROL CONSOLE AND ITS INDICATORS

8

HA-266

MEANING

!
!
!

!

!

!

Successful key entry, a pacifier tone
Successful code entry for the specific function
Unsuccessful code entry for the specific function
Wrong code number entered
Unauthorized command attempted
Code entry time expired, 10 seconds maximum per digit is allowed

SOUND

1 short beep
2 short beeps
5 short beeps

!
!
!

!

!
!

!

!

Exit delay expired, system is armed
Battery voltage low, AC power failure
Exit delay time

Entry delay time

The DAP jumper is ON
The telephone line is faulty after line fault testing

System can not be armed instantly due to

Duress code is entered but the communicator is not working

ARM PROHIBITED

1 long beep
1 short beep/30 seconds
Continuous beeping at

0.5 second interval

Continuous 5 short

beeps/5 seconds interval
2 beeps + 5 beeps

ALARM REPORTING AND ACKNOWLEDGEMENT

!

!

!

In alarm condition, except the local alarm, the system will also send alarm report to the

monitor station and the recorded message to the programmed telephones if the

communicator and the auto dialer are enabled.

The communicator has the priority to dial. After the communicator dialing is finished, the

system will start to dial the telephone numbers stored in the auto dialer.

If

is selected, the auto dialer will send the recorded message after the line

is through.

OPTION

SELECTED

OPTION

SELECTED

1) When you pick up the phone, you will hear the recorded alarm reporting message (

. At the end of the message, the dialer generates a BEEP tone and then waits 3

seconds for you to acknowledge.

2) The acknowledgement signal can be given by pressing the [1] button on your telephone

after the BEEP within 3 seconds.

1 - - - - - - - - -

3) Without an acknowledgement, the message will be repeated until the maximum number of

message is reached. The dialer will call the remaining numbers and will then retry the

numbers that did not acknowledge repeatedly until the maximum number of dialing attempts

are reached.

4) On

reporting mode, receiving an acknowledgement signal from a SINGLE

telephone in a group of 4

is sufficient to

consider the current event closed and call off the dialer session. The remaining 3 telephones

are there for backup purposes only.

5) On

reporting mode, an acknowledgement signal must be received from each

telephone in the group of 4

before the current event is considered

to be reported and closed.

VOICE MESSAGE

BACKUP

NON-BACKUP

RECEIVE AN ALARM REPORTING MESSAGE AND GIVING ACKNOWLEDGEMENT

Please put a " " in the box showing your selected option:

NON-BACKUP REPORTING

BACKUP REPORTING

(DEFAULT)

20

seconds)

(it

must be a tone dialing telephone)

(the dialer can store 4 telephone numbers maximum)

(if 4 numbers are stored)

ON YOUR TELEPHONE KEYBOARD

69

HA-266

Summary of Contents for HA-266

Page 1: ...NUMBER HA 266 Rev 0 An Innovative Product Developed By PROTECT ON SYSTEMS LTD www protect on com 6 ZONE ALARM CONTROL PANEL WITH AUTO DIALER AND COMMUNICATOR HA 266 FOR HOME AND OFFICE PROTECTIONS OWN...

Page 2: ...ls you how to operate the system precisely To get most from the system we suggest that you take time to read through the manual to get acquainted with its features and all the operating procedures PRO...

Page 3: ...4 PROGRAMMING THE PANEL 15 Alarm Reporting Chart 5 The Master Control Console 6 Optional Control Console 6 The LED Light Indicators 7 The Sound Indicators 8 The Terminals On Printed Circuit Board 9 Un...

Page 4: ...5 THE AC AND BATTERY POWER 48 GENERAL SPECIFICATION 50 OPENING THE CABINET FOR SERVICE 51 TABLE OF CONTENTS INSTALLATION SECTION 4 4 HA 266 NOTE 5 BEEPS 2 BEEPS 5 BEEPS ARM PROHIBITED FORCED TO ARM i...

Page 5: ...ACCESS THE SYSTEM BY TELEPHONE 72 HA 266 INTRODUCTION HA 266 is a compact Alarm Control Panel with 6 hardware protection zones and 2 software zones for panic and duress alarms which is designed for ho...

Page 6: ...tion REMOTE ACCESS ENABLED RINGS TO PICK UP LINE REMOTE ACCESS DISABLED OPTION SELECTED 1 Ring the number that the system is connected to In most cases that is the home telephone number of the owner 2...

Page 7: ...equired enabled 1 on hook ALARM REPORTING AND ACKNOWLEDGEMENT 70 HA 266 FLASHING FLASHING FAST FLASHING FAST WITH STOPPING INTERVAL FLASHING SLOW FLASHING TWICE Zone is or was in alarm Zone is in alar...

Page 8: ...d the auto dialer will send the recorded message after the line is through OPTION SELECTED OPTION SELECTED 1 When you pick up the phone you will hear the recorded alarm reporting message At the end of...

Page 9: ...NUMERIC MESSAGE Dialing to an auto pager station from the dialer If you wish the system to contact an auto pager the message form should be selected Please see INSTALLATION SECTION for details 3 Exit...

Page 10: ...il the end of the exit delay System will be armed after exit delay expired The system is disarmed and reset if there was no alarm occurred It is ready for re arming The system is disarmed but with ala...

Page 11: ...code location 11 18 you wish to change its user code key in the new USER CODE and validate by NEW 3 Exit the programming mode by pushing PROGRAM IMPORTANT NOTE INSTALLATION SECTION PROGRAM CHANGE AND...

Page 12: ...ng the incoming telephone line The system connects the house telephone set to the telephone line in normal condition and it picks up the line for the communicator or the auto dialer whenever it goes i...

Page 13: ...tor station test COMMUNICATOR TELEPHONE NO 2 To initiate auto dialer 1st telephone test DIALER TELEPHONE NO 1 To initiate auto dialer 2nd telephone test DIALER TELEPHONE NO 2 To initiate auto dialer 3...

Page 14: ...ber for auto dialer Nil nil Dialing attempts for communicator 4 Code 4 Dialing attempts for auto dialer 4 Code 4 Recorded message repeats for auto dialer 4 Code 4 Dialing backup non backup selection N...

Page 15: ...BATTERY LOW LOW NORMAL LOW NORMAL NOTE LOW TEST THE BACK UP BATTERY PERIODIC DAILY EVERY 24 HOURS BATTERY TEST ENABLED WEEKLY EVERY 7 DAYS BATTERY TEST ENABLED PERIODIC BATTERY TEST DISABLED PROGRAMMI...

Page 16: ...ER CODE VALIDATION 0 1 2 TO 5 DIGITS START THE PROGRAMMING PROGRAMMING THE PANEL 16 HA 266 ON OFF DAP EMERGENCY CASES MAKE A PANIC ALARM MAKE A DURESS ALARM A Software Zone A Software Zone At anytime...

Page 17: ...OCATION CLIENT CODE VALIDATION 10 4 DIGITS The client code is the client s identification number it must be programmed with 4 digits The system will reject the code if it is not exact 4 digits The cli...

Page 18: ...The system exhibits the following behaviours when the duress code is entered System behaviours Important Notes the siren strobe USING THE DURESS CODE PROGRAMMING THE PANEL BEFORE KEYING IN THE DURESS...

Page 19: ...The zone gives entry delay according to the time setting on the entry delay timer 2 The purpose of entry delay 1 and entry delay 2 is to provide operation convenience for the owner to reach the panel...

Page 20: ...0 seconds DEFAULT DEFAULT 30 seconds ENTRY DELAY 1 DEFAULT terminal 9 DEFAULT 300 seconds PROGRAMMING THE PANEL 20 HA 266 TRIGGERING OPTIONS Your system has been programmed for one of the following tr...

Reviews: