TEST YOUR SYSTEM

Please make sure that the system is in DISARMED mode when you perform the tests.

(DEFAULT)

(when AC

or DC power is firstly connected)

STANDBY BATTERY TESTING ROUTINES

The system can be programmed to perform dynamically and automatically test of its standby

battery with the options of periodic test and manual test.

The test takes 2 minutes. The

LED will flash during the test.

AC power is turned OFF in order to monitor the battery under load during the test.
Two beeps will be generated and the

LED will be OFF if the battery is normal.

If the battery is low or dead, five beeps will be generated, the

LED will be ON. The

control console will continuously generate the warning signal of one short beep per 30

seconds until the next test.
A battery status report will be sent to the monitor station on the following two testing results

if the communicator is enabled:
1) The battery is

A battery

report.

2) The battery resumes

but it was

A battery

report.

No report will be given if the battery is normal in this test and it was also normal in the last

test.

1) The system will refuse to initiate the standby battery dynamic test in alarm condition, or, in

the condition of AC power failure, but the system will send a battery low report automatically

before battery exhausting if the battery is

lasting for more than two minutes.

2) The standby battery should be replaced every two to three years with a rechargeable 12V,

1.2Ah, lead acid battery.

The system can be programmed with the following options for periodic testing of the back-up

battery, please put a " " in the box showing your selected option:

OPTION

SELECTED

OPTION

SELECTED

OPTION

SELECTED

The counting of the periodic test starts at the time when the system is power-up

.

The time counting of the periodic test is not affected by the manual battery test.

!

!

!

!

!

!

!

BATTERY

BATTERY

BATTERY

LOW

LOW

NORMAL

LOW

NORMAL

NOTE:

LOW

TEST THE BACK-UP BATTERY -- PERIODIC

DAILY (EVERY 24 HOURS) BATTERY TEST ENABLED

WEEKLY (EVERY 7 DAYS) BATTERY TEST ENABLED

PERIODIC BATTERY TEST DISABLED

PROGRAMMING THE PANEL

You may program the panel from the system control console. Firstly, you are required to make

the system in programming mode, then key in the two digit

, followed immediately by the desired programming values

, then press

the [#] key to store the data. The console will beep twice to confirm the data is successfully

stored, and that 5 beeps will be generated for unsuccessful data entry. If you are not sure that

the correct programming values have been entered, program the programming location again.

After programming is finished, press the [ ] key twice to leave programming mode.
The maximum allowable time for each digit entry is 10 sec

For the owner's convenience in programming at the first time, the factory has put a Master Code

1234 into the system. The owner can use this code for the system to enter to programming mode.
To compromise security, in all cases, the owner should program a personal Master Code to

invalidate the factory set Master Code.

FACTORY SET

MASTER CODE

VALIDATION

The console will beep twice to confirm that the system is in programming mode.
The

LED is ON.

In the case that the factory set Master Code was replaced by your own Master Code, you have

to use your personal Master Code to enter to programming mode.

The console will beep twice to confirm that the system is in programming mode.
The

LED is ON.

Programming Location or the

address

(program data)

PROGRAM

PROGRAM

1. USE THE FACTORY SET MASTER CODE

2. USE YOUR OWN MASTER CODE

!

!

!

!

MASTER CODE

VALIDATION

onds.

1 2 3 4

ATTENTION:

Please make sure that the alarm control panel is firmly fixed to the metal box before

applying power to the system. Otherwise, the tamper switch will be triggered instantly to

give alarm and there will be no user code available for turning off the alarm before the

system is programmed.

HOW TO ENTER PROGRAMMING MODE

MASTER CODE

15

HA-266

Summary of Contents for HA-266

Page 1: ...NUMBER HA 266 Rev 0 An Innovative Product Developed By PROTECT ON SYSTEMS LTD www protect on com 6 ZONE ALARM CONTROL PANEL WITH AUTO DIALER AND COMMUNICATOR HA 266 FOR HOME AND OFFICE PROTECTIONS OWN...

Page 2: ...ls you how to operate the system precisely To get most from the system we suggest that you take time to read through the manual to get acquainted with its features and all the operating procedures PRO...

Page 3: ...4 PROGRAMMING THE PANEL 15 Alarm Reporting Chart 5 The Master Control Console 6 Optional Control Console 6 The LED Light Indicators 7 The Sound Indicators 8 The Terminals On Printed Circuit Board 9 Un...

Page 4: ...5 THE AC AND BATTERY POWER 48 GENERAL SPECIFICATION 50 OPENING THE CABINET FOR SERVICE 51 TABLE OF CONTENTS INSTALLATION SECTION 4 4 HA 266 NOTE 5 BEEPS 2 BEEPS 5 BEEPS ARM PROHIBITED FORCED TO ARM i...

Page 5: ...ACCESS THE SYSTEM BY TELEPHONE 72 HA 266 INTRODUCTION HA 266 is a compact Alarm Control Panel with 6 hardware protection zones and 2 software zones for panic and duress alarms which is designed for ho...

Page 6: ...tion REMOTE ACCESS ENABLED RINGS TO PICK UP LINE REMOTE ACCESS DISABLED OPTION SELECTED 1 Ring the number that the system is connected to In most cases that is the home telephone number of the owner 2...

Page 7: ...equired enabled 1 on hook ALARM REPORTING AND ACKNOWLEDGEMENT 70 HA 266 FLASHING FLASHING FAST FLASHING FAST WITH STOPPING INTERVAL FLASHING SLOW FLASHING TWICE Zone is or was in alarm Zone is in alar...

Page 8: ...d the auto dialer will send the recorded message after the line is through OPTION SELECTED OPTION SELECTED 1 When you pick up the phone you will hear the recorded alarm reporting message At the end of...

Page 9: ...NUMERIC MESSAGE Dialing to an auto pager station from the dialer If you wish the system to contact an auto pager the message form should be selected Please see INSTALLATION SECTION for details 3 Exit...

Page 10: ...il the end of the exit delay System will be armed after exit delay expired The system is disarmed and reset if there was no alarm occurred It is ready for re arming The system is disarmed but with ala...

Page 11: ...code location 11 18 you wish to change its user code key in the new USER CODE and validate by NEW 3 Exit the programming mode by pushing PROGRAM IMPORTANT NOTE INSTALLATION SECTION PROGRAM CHANGE AND...

Page 12: ...ng the incoming telephone line The system connects the house telephone set to the telephone line in normal condition and it picks up the line for the communicator or the auto dialer whenever it goes i...

Page 13: ...tor station test COMMUNICATOR TELEPHONE NO 2 To initiate auto dialer 1st telephone test DIALER TELEPHONE NO 1 To initiate auto dialer 2nd telephone test DIALER TELEPHONE NO 2 To initiate auto dialer 3...

Page 14: ...ber for auto dialer Nil nil Dialing attempts for communicator 4 Code 4 Dialing attempts for auto dialer 4 Code 4 Recorded message repeats for auto dialer 4 Code 4 Dialing backup non backup selection N...

Page 15: ...BATTERY LOW LOW NORMAL LOW NORMAL NOTE LOW TEST THE BACK UP BATTERY PERIODIC DAILY EVERY 24 HOURS BATTERY TEST ENABLED WEEKLY EVERY 7 DAYS BATTERY TEST ENABLED PERIODIC BATTERY TEST DISABLED PROGRAMMI...

Page 16: ...ER CODE VALIDATION 0 1 2 TO 5 DIGITS START THE PROGRAMMING PROGRAMMING THE PANEL 16 HA 266 ON OFF DAP EMERGENCY CASES MAKE A PANIC ALARM MAKE A DURESS ALARM A Software Zone A Software Zone At anytime...

Page 17: ...OCATION CLIENT CODE VALIDATION 10 4 DIGITS The client code is the client s identification number it must be programmed with 4 digits The system will reject the code if it is not exact 4 digits The cli...

Page 18: ...The system exhibits the following behaviours when the duress code is entered System behaviours Important Notes the siren strobe USING THE DURESS CODE PROGRAMMING THE PANEL BEFORE KEYING IN THE DURESS...

Page 19: ...The zone gives entry delay according to the time setting on the entry delay timer 2 The purpose of entry delay 1 and entry delay 2 is to provide operation convenience for the owner to reach the panel...

Page 20: ...0 seconds DEFAULT DEFAULT 30 seconds ENTRY DELAY 1 DEFAULT terminal 9 DEFAULT 300 seconds PROGRAMMING THE PANEL 20 HA 266 TRIGGERING OPTIONS Your system has been programmed for one of the following tr...

Reviews: