THE SYSTEM CONTROL CONSOLE AND ITS INDICATORS
(2) OPTIONAL CONTROL CONSOLE
One optional control console can be connected to the system at remote location
(1) THE MASTER CONTROL CONSOLE
The Connection Terminals:
(+) 12V
:
( ) 12V
:
CLOCK
:
DATA
:
TAMPER N.C. :
+12V power input terminal, connect it to wire 5.
Common grounding point, connect it to wire 9.
The clock of the system, connect it to wire 6.
The data signal of the system, connect it to wire 7.
These are the connection terminals of the tamper switch on the control console.
Connection of it is optional. If required, connect it to a normally closed (N.C.)
24-hour zone.
Optional control console is required to purchase separately.
The optional control console can be used for HA-268 and HA-266, zone indicator 7
is not used and 8 is the tamper zone (T) in HA-266.
-
NOTE:
D
D
6
HA-266
REMOTE CONTROL OF THE SYSTEM BY TELEPHONE
The HA-266 has been designed to allow the owner to telephone the system remotely
to check its arm-disarm status, to make arm-disarm control or
to request the communicator for a current status report sending to the monitor station or to the
owner's pocket pager. The call can be made from any telephone capable of tone dialing,
including DTMF capable mobile telephones.
Please put a " " in the box showing your selected option:
REMOTE ACCESS ENABLED
RINGS TO
PICK-UP
(
)
LINE
REMOTE ACCESS DISABLED
OPTION
SELECTED
1. Ring the number that the system is connected to. In most cases that is the home telephone
number of the owner.
2. After the pre-set number of rings
the system will
answer the phone with one of the following answering beeps to show its current status.
3. If you only wish to check on the CURRENT STATUS of the alarm system, without making
any change, simply hang up the phone after the answering beep is heard.
4. If you wish to change the status on the system, please enter the appropriate command code
using the telephone keypad after the answering beep is heard.
For obvious security reasons
can be used for system remote
ARM-DISARM control.
(See
Program Location 83 for details)
DEFAULT: 16
(programmed at Location 83. DEFAULT: 16)
CHECKING THE ARM-DISARM CURRENT STATUS
REMOTE ARM-DISARM THE SYSTEM
THE MEANING OF THE ANSWERING BEEPS--SUMMARY
NOTE:
ONLY USER CODE 1
NO.
1
2
3
4
5
6
7
ANSWERING BEEPS
1 beep
2 beeps
1 beep + 3 beeps
2 beeps + 3 beeps
1 beep + 2 beeps
5 beeps
2 beeps + 5 beeps
System is disarmed
System is armed
System is disarmed, but
Alarm is occurred
System is armed, and
Alarm is occurred
System is disarmed, but
System is in alarm memory, at least one of the protection
zones was in alarm
Unsuccessful code entry, try again
Successful code entry but the function request is rejected
due to system arm prohibited
MEANINGS
!
!
!
!
!
!
!
!
!
!
(due to the 24 hours or the software zones)
71