2. Acyclic parameter table Thyro-C07
Table B: Thyro-C07 controller parameters slot 1-8
Controller parameter
Index
Symbol
Name
Data
type
Value
range
Combo-opt.
1
I_TYP
Controller type current
u16
0…
2
U_TYP
Controller supply voltage
u16
0…1000
3
P_TYP
Controller type output power
u32
0…
6
BETR
Operating mode
u16
0…3
reserved, TAKT, VAR, QTM
7
AN1
Phase angle of 1st half wave
u16
0…180
8
SST
u16
0…1000
9
SDN
Soft stop duration (given)
u16
0…1000
10
T0
Cycle period duration
u16
0…1000
11
MP
Minimum interval
u16
0…10
12
TSMAX
Maximum cycle turn on time
u16
1…T0
13
TSMIN
Minimum cycle turn on time
u16
0…T0
14
V_IE
Front pulse stop
u16
0…180
15
H_IE
Back pulse stop
u16
0…180
16
RE
Control (analog output value)
u16
0…9
Uload2, Uload eff, Iload2, Iload eff, reserved, real power,
reserved, reserved, without regulation, temperature
17
TI_1
PI controller, I part
u16
0= aus
0…65535
18
KP_1
PI controller, P part
u16
0= aus
0…65535
19
KR_1
PI controller, counter P part
u16
0…65535
20
Temperature coefficient of the heating tape
u16
0…65535
21
UEMA
Effective voltage setpoint maximum
u16
0…
22
IEMA
Effective current setpoint maximum
u16
0…
23
PMA
Power setpoint maximum
u32
0…
24
SW_ENABLE
Setpoint activation
u16
0…3
bit0=1 setpoint x2.4 active, bit1=1 setpoint master active
27
SW_REGLER
Setpoint x2.4
u16
0…4096
28
OF_1
Actual value output offset 1
u16
0…4096
29
FA_1
Scale end value actual value output 1
u16
0…4096
30
SPG_MIN
Mains voltage monitoring min.
u16
0…1000
31
SPG_MAX
Mains voltage monitoring max.
u16
0…1000
32
UN_S
Undercurrent monitoring
u16
0…1
off, on
33
RELAIS_CTRL_2
Relay configuration 2
u16
0…65535
bit coded
34
LASTBRUCH_MIN_
ABS
Load fault, minimum value
u16
0…4505
36
SYNC_ADR
Synchro cycle address
u16
0…65535
37
IMAB
Pulse switch-off in case of failure
u16
0…65535
bit coded
38
STA_RE
Control start controller analog setpoint
u16
0…65535
39
STE_RE
Control end controller analog setpoint
u16
0…65535
41
MOSI_FA
Peak current value limit
u16
0…4096
42
DAC_1_CTRL
Analog output configuration 1
u16
0…11
44
VERS_T
Version day
u16
1…31
45
VERS_M
Version month
u16
1…12
46
VERS_J
Version year
u16
0…9999
48
Controller inhibit
u16
0…1
off, on
49
RELAIS_CTRL
Relay configuration 1
u16
0…65535
bit coded
50
Save
u16
0…1
off, save
56
MITTEL
Averaging analog output 1
u16
0…65535
84
TEMP
Temperature
u16
-50…150
109
MITTEL_2
Averaging analog output 2
u16
0…65535
110
OF_2
Actual value output offset 2
u16
0…4096
111
FA_2
Scale end value actual value output 2
u16
0…4096
112
DAC_2_CTRL
Analog output configuration 2
u16
0…11
115
MITTEL_3
Averaging analog output 3
u16
0…65535
116
OF_3
Actual value output offset 3
u16
0…4096
117
FA_3
Scale end value actual value output 3
u16
0…4096
118
DAC_3_CTRL
Analog output configuration 3
u16
0…11
119
U_MIN
Voltage limit minimum
u16
0…65535
120
U_MAX
Voltage limit maximum
u16
0…65535
121
I_MIN
Current limit minimum
u16
0…65535
122
I_MAX
Current limit maximum
u16
0…65535
123
P_MIN
Power limit minimum
u32
0…
124
P_MAX
Power limit maximum
u32
0…