16
Tab. 5b Thyro-S Status
6.4 Input and output data Thyro-A
Tab. 6 Cyclic input and output data with Thyro-A 1A...H1
Tab. 7 Cyclic input and output data with Thyro-A 1A...HRL1
Description
Bit
LEDs
Relay
Pulse inhib active
Bit 0
none
open
(bridge X2.1-X2.2 open)
Bit 0
none
open
Mains frequency is 60Hz
Bit 2
none
open
Relay status
Bit 8
none
open
(0=relay off / 1=relay on)
Bit 8
none
open
Device switched off
Bit 9
--
closed
Wrong device
Bit 10
--
----
Bus module active
(0=no bus module / 1=bus module active)
Bit 11
none
----
Thyristor short-circuit
Bit 14
Test LED and Load Fault LED
flashing alternately slowly
----
Offset
Input data, actual values
Data type
Size
Unit
0
Load voltage L1
float
4
[V]
4
Mains voltage L1
integer
2
[V]
6
Switch-on time TS
integer
2
[period]
8
Switch-on angle alpha
integer
2
[0.01 °el]
10
Total setpoint
integer
2
4096=100%
12
Fault (see table 14b)
integer
2
-
14
Status (see table 14b)
integer
2
-
Offset
Output data, setpoint
Data type
Size
Unit
0
Master setpoint
integer
2
4096=100%
Offset
Input data, actual values
Data type
Size
Unit
0
Load voltage L1
float
4
[V]
4
Load current L1
float
4
[A]
8
Mains voltage L1
integer
2
[V]
10
Switch-on time TS
integer
2
[period]
12
Switch-on angle alpha
integer
2
[0.01 °el]
14
Total setpoint
integer
2
4096=100%
16
Fault (see table 14b)
integer
2
-
18
Status (see table 14b)
integer
2
-
Offset
Output data, setpoint
Data type
Size
Unit
0
Master setpoint
integer
2
4096=100%