“i57“ – code: mcb Vbat voltage plausability
•
alarm will be set if Vbat is detected higher than 440V or lower than 215V.
rem.: with Vbat voltage the calculation of the motor resistance is executed
“i58“ – code: motor plug connection
•
alarm will be set if motor connection is detected wrong based on motor currents measurements.
if currents are inside the thresholds (+/- 10mA); debounce is set to 2 seconds
“i59“ – code: mcb current read adc - fault
•
alarm is set if there is detected a fault in the current reading chain on mcb; incl. adc conversion
•
it´s verified by the current sum of the three motor phases which should be nearly zero; if the sum
is higher than 40mA for longer than 300 ms than the assumption is that something is wrong.
“i5A“ – code: over temperature motor windings
•
internal warning is set when the internal calculations based on the measured currents lets expect that
the temperature are out of standard limits (200°C – with 40°C margin due to measurement and
calculation tolerances).
•
the threshold value for the warning is 200 – 70 (max. ambient temperature inside the dishwasher) - 10
(activation margin) = 120°C
warning level is given
•
if the warning is set, than the motor is stopped and a new winding resistance calculation is performed .
in this way the real temperature can be calculated – temp. calculation is based on ref. resistance of
motor windings at 22°C.
-
the alarm is set if the value is greater than the threshold 178°C (200 – 22).
rem.: the alarm is reset by MCB after verification procedure with baseboard.
“i60” Code - family : Heating Element Problem
“i60” – code: heating
•
The alarm is stored and displayed only in service mode; the washing programme continues without the
activation of the heating element.
•
During the heating phases, the rise in temperature is monitored with an update every 3 min.
•
Within these 3 minutes, the temperature must rise by at least 1 °C.
“i61” – code: heating over temperature
•
if water temperature is detected higher than 78°C, cycle is stopped.
(rem.: origin of this alarm is problem on visi plastic doors)
“i70” Code - family : Thermistor problem
“i70” – code: NTC sensor value out of range
•
The alarm is stored and displayed only in service mode; the washing program continues without the
activation of the heating element.
•
Monitoring starts immediately after the program has been started.
•
The voltage measured at the ends of the NTC must be between 0.04 and 4.7 V.
Summary of Contents for EDW1103
Page 6: ...SOE PR 6 599 72 48 93 3 2 Fully Integrated EDW1953 EDW1103 ...
Page 8: ...SOE PR 8 599 72 48 93 EDW750 EDW1850 EDW1950 EDW3510 EDW2500 SWISS ...
Page 9: ...SOE PR 9 599 72 48 93 EDW 500 EDW 503 EDW 1503 ...
Page 14: ...SOE PR 14 599 72 48 93 6 2 3 EDW750 6 2 4 EDW1850 1950 6 2 5 EDW1953 TOUCH ...
Page 25: ...SOE PR 25 599 72 48 93 7 13 EDW750 7 14 EDW1850 1950 7 15 EDW1953 TOUCH ...
Page 56: ...SOE PR 56 599 72 48 93 10 14 EDW1xxx 2G operating diagram ...
Page 57: ...SOE PR 57 599 72 48 93 10 15 EDW3000 operating diagram single phase motor ...
Page 58: ...SOE PR 58 599 72 48 93 10 16 EDW3000 operating diagram three phase Inverter motor ...