SOE/PR
17
599 72 48-93
7.1.2
Deleting alarm memory/LED test
1. Hold down button
S1
2. Turn the knob anti-clockwise to
Position 5
�
LEDs LD0 and LD1 flash
�
release button
S1
3. Turn the knob to
Position 4
4. Press button
S1
�
all LEDS flash for 30 sec
7.1.3
Functional test cycle
7.1.3.1
Cycle setting
1. Hold down button
S1
2. Turn the knob anti-clockwise to
Position 5
�
LEDs LD0 and LD1 flash
�
release button
S1
3. Turn the knob to
Position 3
�
press button
S1
�
the cycle starts: during its progress, the programme
behaves like a normal cycle
�
LED LD1 flashes
N.B.
: a
t the beginning of the next programme after the test cycle, the resins are washed. The overall duration
of the cycle is approximately 50 minutes.
7.1.4
Quitting diagnostics mode
To quit diagnostics mode, press button
S0
and turn off the appliance
or wait
60 seconds
: the LEDS are turned on and the appliance is on stand-by awaiting your selection
Summary of Contents for EDW1103
Page 6: ...SOE PR 6 599 72 48 93 3 2 Fully Integrated EDW1953 EDW1103 ...
Page 8: ...SOE PR 8 599 72 48 93 EDW750 EDW1850 EDW1950 EDW3510 EDW2500 SWISS ...
Page 9: ...SOE PR 9 599 72 48 93 EDW 500 EDW 503 EDW 1503 ...
Page 14: ...SOE PR 14 599 72 48 93 6 2 3 EDW750 6 2 4 EDW1850 1950 6 2 5 EDW1953 TOUCH ...
Page 25: ...SOE PR 25 599 72 48 93 7 13 EDW750 7 14 EDW1850 1950 7 15 EDW1953 TOUCH ...
Page 56: ...SOE PR 56 599 72 48 93 10 14 EDW1xxx 2G operating diagram ...
Page 57: ...SOE PR 57 599 72 48 93 10 15 EDW3000 operating diagram single phase motor ...
Page 58: ...SOE PR 58 599 72 48 93 10 16 EDW3000 operating diagram three phase Inverter motor ...