SOE/PR
31
599 72 48-93
“i45” – code: Calibration invalid, pressure signal too low
•
the warning is set if the sensor signal is out of range for an empty dw, signal low.
•
the signal range for calibration is defined in MCF
“i46” – code: Calibration invalid, pressure signal too high
•
the warning is set if the sensor signal is out of range for an empty dw, signal high.
•
the signal range for calibration is defined in MCF
“i50” Code - family: Washing Motor Problem
“i51” – code: Asynchronous motor problem
•
Acoustic signal and visual alarm, depending on the appliance customisation; the programme is
suspended.
•
The washing pump runs without being activated by the software, the cause is a short-circuit.
•
The heating element is not activated.
•
If the alarm occurs, the fill solenoid valve is activated up to the level pressure switch tripping point, then
the cycle is suspended.
•
Time limit set: 8 sec.
“i52” – code: bldc motor – abnormal extra current detected
•
MCB hardware supervising – will be set when abnormal extra current of about 1.3 amps are detected.
“i53” – code: bldc motor – over current
•
alarm will be set when the max. allowed current will be detected higher.
•
max. allowed current is set to 1.3 A
“i54” – code: bldc motor rotor locked
•
alarm will set when the motor locked condition is detected during start of motor and also during the
running motor; reasons can be dirt, too high load, mechanical problems on impeller
“i55” – code: mcb Vbat overvoltage
•
alarm is set when the Vbat voltage on motorcontrolboard will be detected greater the 400Vdc
“i56” – code: mcb Vbat undervoltage
•
alarm is set when the Vbat voltage on motorcontrolboard will be detected lower than 255Vdc
Summary of Contents for EDW1103
Page 6: ...SOE PR 6 599 72 48 93 3 2 Fully Integrated EDW1953 EDW1103 ...
Page 8: ...SOE PR 8 599 72 48 93 EDW750 EDW1850 EDW1950 EDW3510 EDW2500 SWISS ...
Page 9: ...SOE PR 9 599 72 48 93 EDW 500 EDW 503 EDW 1503 ...
Page 14: ...SOE PR 14 599 72 48 93 6 2 3 EDW750 6 2 4 EDW1850 1950 6 2 5 EDW1953 TOUCH ...
Page 25: ...SOE PR 25 599 72 48 93 7 13 EDW750 7 14 EDW1850 1950 7 15 EDW1953 TOUCH ...
Page 56: ...SOE PR 56 599 72 48 93 10 14 EDW1xxx 2G operating diagram ...
Page 57: ...SOE PR 57 599 72 48 93 10 15 EDW3000 operating diagram single phase motor ...
Page 58: ...SOE PR 58 599 72 48 93 10 16 EDW3000 operating diagram three phase Inverter motor ...