15
CONVERSIONS
13) REPLACING THE INJECTORS
The burners can be adapted to different types of
gas by mounting injectors suited to the type of gas
in question. To do this, first remove the burner tops
using a wrench “B”. Now unscrew injector “A” (see
fig. 16) and fit a injector corresponding to the utilized
type of gas in its place.
It is advisable to strongly tighten the injector in
place.
After the injectors have been replaced, the
burners must be regulated as explained in
paragraphs 10. The technician must reset any
seals on the regulating or pre-regulating devices.
The envelope with the injectors and the labels
can be included in the kit, or at disposal to the
authorized customer Service Centre.
For the sake of convenience, the nominal rate table
also lists the heat inputs of the burners, the
diameter of the injectors and the working pressures
of the various types of gas.
BURNER ARRANGEMENT ON THE HOT PLATE
LPG
28 - 30
218
88
750
3000
41
1
RAPID
LPG
37
214
88
750
3000
41
NATURAL
20
286
115 Y
750
3000
41
LPG
28 - 30
127
68
500
1750
32
2
SEMIRAPID
LPG
37
125
68
500
1750
32
NATURAL
20
167
98 Z
500
1750
32
LPG
28 - 30
73
50
400
1000
30
3
AUXILIARY
LPG
37
71
50
400
1000
30
NATURAL
20
95
72 X
400
1000
30
LPG
28 - 30
244
93
1400
3350
62
4
ULTRA RAPID
LPG
37
239
93
1400
3350
62
NATURAL
20
319
124 Y
1400
3350
62
OTHER MARKETS
BURNERS
N°
DESCRIPTION
GAS
NORMAL
PRESSURE
NORMAL
RATE
INJECTOR
DIAMETER
NOMINAL
HEAT INPUT (W)
mbar
g/h
l/h
1/100 mm
Min.
Max.
1/100 mm
FIG. 16
BY PASS