CONVERSIONS
BURNER ARRANGEMENT ON THE HOT PLATE
LPG
30
218
88
750
3000
41
1
RAPID
TOWN
10
625
330 3
750
3000
41
LPG
30
127
68
500
1750
32
2
SEMIRAPID
TOWN
10
365
200 2
500
1750
32
LPG
30
73
51
400
1000
30
3
AUXILIARY
TOWN
10
208
150 1
400
1000
30
LPG
30
244
95
1400
3350
62
4
ULTRA RAPID
TOWN
10
646
350 6
1400
3100
62
HONG KONG MARKET
BURNERS
N°
DESCRIPTION
GAS
NORMAL
PRESSURE
NORMAL
RATE
INJECTOR
DIAMETER
NOMINAL
HEAT INPUT (W)
mbar
g/h
l/h
1/100 mm
Min.
Max.
1/100 mm
BY PASS
LPG
30
218
88
750
3000
41
1
RAPID
NATURAL
20
247
115 Y
750
3000
41
TOWN (Shanghai)
10
716
260 3
750
3000
41
TOWN (Guangzhou)
20
383
140 1
750
3000
41
LPG
30
127
68
500
1750
32
2
SEMIRAPID
NATURAL
20
144
98 Z
500
1750
32
TOWN (Shanghai)
10
418
185 5
500
1750
32
TOWN (Guangzhou)
20
223
110 1
500
1750
32
LPG
30
73
51
400
1000
30
3
AUXILIARY
NATURAL
20
82
72 X
400
1000
30
TOWN (Shanghai)
10
239
135 11
400
1000
30
TOWN (Guangzhou)
20
128
87
400
1000
30
LPG
30
244
95
1400
3350
62
4
ULTRA RAPID
NATURAL
20
276
124 Y
1400
3350
62
TOWN (Shanghai)
10
740
330 3
1400
3100
62
TOWN (Guangzhou)
20
396
165 2
1400
3100
62
CHINA MARKET
BURNERS
N°
DESCRIPTION
GAS
NORMAL
PRESSURE
NORMAL
RATE
INJECTOR
DIAMETER
NOMINAL
HEAT INPUT (W)
mbar
g/h
l/h
1/100 mm
Min.
Max.
1/100 mm
BY PASS
16
Summary of Contents for 25658G-M