background image

Keep children away from the controller’s electronics and the battery compartment! 

All work must be carried out in accordance with national electrical regulations and the relevant local speciafications.  

1.2

 

Exemption from Liability 

We cannot accept liability for damage caused by disregarding these instructions within a radius of the controller even if this 
damage occurs due to malfunctioning of the controller caused by incorrect installation or programming. 
It is neither possible for the manufacturer to monitor compliance with these instructions nor the conditions prevailing and 
methods used during installation, operation, use and maintenance of the system controller. Incorrect execution of the 
installation may lead to material damage and to subsequent danger to people. The installer himself must be liable for such 
damage.  
We therefore accept no responsibility or liability for losses, damage or costs arising as a result of faulty installation; incorrect 
operation, improper use and maintenance or that is in any way connected thereto.  
Likewise we accept no responsibility for patent infringements or infringements of Third Party rights resulting from the use of 
this system controller. The manufacturer reserves the right to make modifications with regard to the product, technical data 
or assembly and operating instructions without prior notice.  
The user shall be responsible for use of the controller in areas of application not defined by the manufacturer  

Caution: opening the device up and operation contrary to the intended purpose lead to loss of warranty.  

1.3

 

Area of Use 

The system controller is used in photovoltaic power supplies with battery store for the hobby and leisure sector, residential, 
business and trade sectors as well as small businesses.  

1.4

 

Installation Instruction 

The controller is only suitable for use indoors protected against the effects of weather such as rain and solar 
radiation. 

The controller must be installed in the same room as the battery for the following reasons: 
A built-in temperature sensor detects the ambient temperature  

SLX Night Operating Instructions 

page 4 

 

Summary of Contents for PR 0606 Night

Page 1: ...PHOTOVOLTAIK PHOTOVOLTAIC PHOTOVOLTAIQUE FOTOVOLTAICA 702 287 08 18 EN Installation and operating instructions Programmable Nightlight Function Controller PR 0606 Night PR 1010 Night...

Page 2: ...s 7 4 1 1 Programming LED 7 4 1 2 Info LED 8 4 1 Charging Status LED 8 3 4 Pushbuttons 9 2 5 Programming the Controller 9 5 1 Programming Operations 9 5 2 Operations for Selecting Possible Settings 10...

Page 3: ...de energise the modules completely by using this cover Double the values of the system voltages may occur during assembly and electrical installation in the direct current circuit of the photovoltaic...

Page 4: ...orrect operation improper use and maintenance or that is in any way connected thereto Likewise we accept no responsibility for patent infringements or infringements of Third Party rights resulting fro...

Page 5: ...service life is lengthened considerably The charging procedure takes place in accordance with the IU characteristic as a function of temperature Furthermore the battery s previous history determines a...

Page 6: ...inst polarity reversal open circuit and short circuit on all inputs and outputs 3 Connection of the Controller Recommended Connection Sequence 1 Battery charge controller as close as possible to batte...

Page 7: ...connection faults e g no battery connected battery connected to load output wrong system voltage 4 Controller Elements LED Status lamps Programming LED Information LED Charging status LED Next butto...

Page 8: ...as elapsed 4 1 3 Charging Status LED The charging status LED changes colour from green to red depending on the charging status Normal mode continuously lit Warning deep discharge protection rapid flas...

Page 9: ...nd green when the load is switched on Acknowledge a setting in the submenu Switching from main menu to submenu Returning from submenu to main menu Please consult the following section for procedures f...

Page 10: ...as been found acknowledge with the OK button This gives access to the respective settings possible OK 5 2 Operations for Selecting Possible Settings In each of the submenus there is the possibility to...

Page 11: ...ontrol type 14 7 Volt 15 0 Volt Liquid Gel Charge status controlled Voltage controlled OK OK Next Next Next Next Next OK OK OK OK Next Next OK All changes are permanently stored on leaving programming...

Page 12: ...4 Permanent night light Yes No 5 Factory settings Yes No OK OK OK OK Next Next Next Next Enter the next submenus in Night version SLX Night Operating Instructions page 12...

Page 13: ...etectors Yes No Exit programming mode Next Next Next OK OK OK OK OK OK Next Next Next Enter evening light setting by acknowledging yes see Section 5 5 Enter morning light setting by acknowledging yes...

Page 14: ...to sunset and during this time the load is switched on all night Since the charge controller learns the time from the brightness curve there may be deviations from the actual time the deviation depend...

Page 15: ...tched on as dusk falls and is switched off again at the time programmed Evening light Yes No In the evening light program acknowledge using yes to specify the time the controller switches off The left...

Page 16: ...ED then lights up green and you may select the following switch on times s Tabelle 4 Yes No Morning light Switch on time 23 00 00 00 01 00 02 00 03 00 04 00 05 00 06 00 07 00 Press the Next button to...

Page 17: ...to 2h 14 7V oder 15 0V Exhaustive dishcarge protection early warning 30 40 Values for voltage controlled 11 1V 11 5V Re set threshold 50 Values for voltage controlled 12 6V Permissible ambient temper...