4.1.2

 

Info – LED  

Green flashing, normal operating mode, everything OK. 
During the day the LED flashes every 2 seconds and at night every 5 seconds.   
 
Red flashing, warning: over-current, -temperature, -voltage. Controller has not yet switched off. 
 

Continuously lit red lamp, controller has switched off, will switch on again automatically when fault has been 
remedied and 1 minute has elapsed.  

4.1.3

 

 Charging Status – LED 

The charging status LED changes colour from green to red depending on the charging status.  

Normal mode: 

continuously lit 

Warning deep discharge protection: 

rapid flashing (4 times a second) 

Active deep discharge protection: 

slowly flashing

 

(every2 seconds) 

If the controller is set to voltage-controlled, the charging status LED displays the battery voltage:  

 
 

100%

80%

60%

40%

30%

Full

Empty

 
Red: 

Battery voltage < 11.5V 

Orange: 

Battery voltage > 11.5V 

Yellow: 

Battery voltage > 12.1V 

Green: 

Battery voltage > 12.7V 

 
 
 
 
 

SLX Night Operating Instructions 

page 8 

 

Summary of Contents for PR 0606 Night

Page 1: ...PHOTOVOLTAIK PHOTOVOLTAIC PHOTOVOLTAIQUE FOTOVOLTAICA 702 287 08 18 EN Installation and operating instructions Programmable Nightlight Function Controller PR 0606 Night PR 1010 Night...

Page 2: ...s 7 4 1 1 Programming LED 7 4 1 2 Info LED 8 4 1 Charging Status LED 8 3 4 Pushbuttons 9 2 5 Programming the Controller 9 5 1 Programming Operations 9 5 2 Operations for Selecting Possible Settings 10...

Page 3: ...de energise the modules completely by using this cover Double the values of the system voltages may occur during assembly and electrical installation in the direct current circuit of the photovoltaic...

Page 4: ...orrect operation improper use and maintenance or that is in any way connected thereto Likewise we accept no responsibility for patent infringements or infringements of Third Party rights resulting fro...

Page 5: ...service life is lengthened considerably The charging procedure takes place in accordance with the IU characteristic as a function of temperature Furthermore the battery s previous history determines a...

Page 6: ...inst polarity reversal open circuit and short circuit on all inputs and outputs 3 Connection of the Controller Recommended Connection Sequence 1 Battery charge controller as close as possible to batte...

Page 7: ...connection faults e g no battery connected battery connected to load output wrong system voltage 4 Controller Elements LED Status lamps Programming LED Information LED Charging status LED Next butto...

Page 8: ...as elapsed 4 1 3 Charging Status LED The charging status LED changes colour from green to red depending on the charging status Normal mode continuously lit Warning deep discharge protection rapid flas...

Page 9: ...nd green when the load is switched on Acknowledge a setting in the submenu Switching from main menu to submenu Returning from submenu to main menu Please consult the following section for procedures f...

Page 10: ...as been found acknowledge with the OK button This gives access to the respective settings possible OK 5 2 Operations for Selecting Possible Settings In each of the submenus there is the possibility to...

Page 11: ...ontrol type 14 7 Volt 15 0 Volt Liquid Gel Charge status controlled Voltage controlled OK OK Next Next Next Next Next OK OK OK OK Next Next OK All changes are permanently stored on leaving programming...

Page 12: ...4 Permanent night light Yes No 5 Factory settings Yes No OK OK OK OK Next Next Next Next Enter the next submenus in Night version SLX Night Operating Instructions page 12...

Page 13: ...etectors Yes No Exit programming mode Next Next Next OK OK OK OK OK OK Next Next Next Enter evening light setting by acknowledging yes see Section 5 5 Enter morning light setting by acknowledging yes...

Page 14: ...to sunset and during this time the load is switched on all night Since the charge controller learns the time from the brightness curve there may be deviations from the actual time the deviation depend...

Page 15: ...tched on as dusk falls and is switched off again at the time programmed Evening light Yes No In the evening light program acknowledge using yes to specify the time the controller switches off The left...

Page 16: ...ED then lights up green and you may select the following switch on times s Tabelle 4 Yes No Morning light Switch on time 23 00 00 00 01 00 02 00 03 00 04 00 05 00 06 00 07 00 Press the Next button to...

Page 17: ...to 2h 14 7V oder 15 0V Exhaustive dishcarge protection early warning 30 40 Values for voltage controlled 11 1V 11 5V Re set threshold 50 Values for voltage controlled 12 6V Permissible ambient temper...

Page 18: ...ter it is discovered Legal guarantee claims are to be directed to the seller The seller must be informed before legal guarantee claims are processed For processing a legal guarantee claim an exact fau...