Advent Communications
209298 - DVE5000 Technical Operation Handbook - CL140042
Page 93 of 110
8.6.3
Remote Bulk Status query
A single command can be sent to query the complete status of the unit. As new features are
regularly added to this unit, the length of the response will grow. In order to help maintain
compatibility, all new settings will be added to the end of the bulk status response. Remote control
software should therefore be written so that longer responses will not cause the control software to
malfunction
Bulk status query
Query
RQSTR
The response is broken down as follows (length and format of the data is the same as for the
individual queries):
Parameter
Data
length
Comments
Output type
1
Carrier
1
Transmit band
1
Transmit gain
5
Transmit frequency
10
OFDM guard interval
1
DVB-S modulation mode
1
DVB-T modulation mode
1
FEC
1
Polarity
1
OFDM bandwidth
1
Modulation output level
5
Modulation output frequency
7
Modulation roll off factor
1
Downlink NIT on/off
1
Downlink frequency
8
Downlink satellite position
8
Downlink direction
1
Downlink polarisation
1
ASI mode
1
ASI bitrate
7
SI service name
10
SI network name
10
PMT PID
4
PCR PID
4
Local service enabled
1
Program ID
5
Scrambling on/off
1