6.3.2
RF OPTIONS
By using the up / down arrow keys, highlight
RF OPTIONS
and press ENTER key.
This screen will be displayed: -
0dB Level: MORE>
- RF Options -
LO:
BUC DC SUPPLY:
Power-on Tx:
BUC DC SUPPLY
: 17V DC may be enabled on the main L-Band output using this menu
option, so as to power an external SHF block Upconverter; Use up / down arrow keys to select,
press ENTER to confirm or ESCAPE to cancel selection.
Note that if the HPA control has been set to “L-band” DC is always present on the L-Band
output to power the remote protocol converter in the block Upconverter.
LO (local Oscillator)
: The output from the DVE5000 is always L-Band between 950MHz and
1750MHz. The front panel display can show the final system output frequency of the system
instead, taking into account the local oscillator frequency of the SHF block Upconverter.
The following choices can be made –
L- Band direct display has no local oscillator frequency – select NONE.
C-Band assumes local oscillator of 4900MHz.
X-Band assumes local oscillator of 6500MHz
Ku-1-Band assumes local oscillator of 11800MHz.
Ku-2 Band assumes local oscillator of 12800MHz.
Ku-3 Band assumes local oscillator of 13050MHz.
Ku-4 Band assumes local oscillator of 16350MHz.
Ku-5 Band assumes local oscillator of 16900MHz.
Ku-6 Band assumes local oscillator of 15450MHz.
Note Ku-6 is “high side LO” so 950MHz = 14.5GHz, 1700Mhz = 13.75GHz.