41
WISE-4000 User Manual
Chapter 3
H
ardware
Installation
3.3
Wiring & Connections
This section introduces basic information on wiring the power supply, I/O units, and
Ethernet connection.
3.3.1
Power Supply Wiring (Not for WISE-4012E)
The system of WISE-4000 is designed for a standard industrial unregulated 24 V
DC
power supply. For further application, it can also 10 to +30 V
DC
of power
input, 200mV peak to peak of power ripple, and the immediate ripple voltage should
be maintained b10 and +30 V
DC
.
Screw terVs and -Vs are for power supply wiring
Figure 3.10 Power Supply Wiring
3.3.2
USB Power (WISE-4012E Only)
The system of WISE-4012E IoT Developer Kit is designed for a standard Micro-B
USB 5V
DC
power supply. Use the provided USB power cable to power up the mod-
ule. Insert the Micro-B USB end to the USB port on the side of the module, and insert
another end to Type-A 5V
DC
USB port such as a PC, notebook, USB power adapter,
USB power bank.
Note!
The wires used should be at least 2 mm.
Note!
The wider or flared part of the USB Micro-B connector is at the front side
of the module, please make sure the direction of the cable before insert-
ing it into the module to prevent the damage to the USB port.
Some USB power banks will automatically switch off, in this case, use a
standard USB power instead.
Summary of Contents for WISE-4000 Series
Page 1: ...User Manual WISE 4000 Series IoT Ethernet I O Module ...
Page 9: ...Chapter 1 1 Product Overview ...
Page 17: ...Chapter 2 2 Product Specifications ...
Page 42: ...WISE 4000 User Manual 34 2 9 4 Block Diagram Figure 2 35 WISE 4060 Block Diagram ...
Page 43: ...Chapter 3 3 Hardware Installation ...
Page 51: ...Chapter 4 4 System Configuration ...
Page 100: ...WISE 4000 User Manual 92 ...
Page 101: ...Appendix A A I O Modbus Mapping Table ...
Page 124: ...WISE 4000 User Manual 116 ...