SKY-8232D Manual V02 20220411
Copyright 2022 Advantech Co. Ltd. All rights reserved
Page 86
Figure 3-24: Sever Management Setup
Table 3-17: Server Management Setup
Group
Setup Item
Access /
Options
Description
None
BMC Self Test Status
Display only
(Passed)
BMC self test status indication
during power on process
OS Watchdog Timer
Enabled
Disabled
If enabled, starts a BIOS timer
which can only be shut off by
Management Software after the
OS loads.
Helps determine that the OS
successfully loaded or follows
the OS Boot Watchdog Timer
OS Wtd Timer
Timeout
5 minutes
10 minutes
15 minutes
20 minutes
Configure the length of the OS
Boot Watchdog Timer. Not
available if OS Boot Watchdog
Timer is disabled.
OS Wtd Timer Policy
Do Nothing
Reset
Power Down
Configure how the system
should respond if the OS Boot
Watchdog Timer expires. Not
available if OS Boot Watchdog
Timer is disabled.
BMC
network
configur
ation
Configuration
Address
Unspecified
static
DynamicBmc
Dhcp
Select to configure LAN
channel parameters statically or
dynamically(by BIOS or BMC).
Unspecified option will not
modify any BMC network
parameters during BIOS phase
BMC
Self test
Erase Log
NO
Yes, On
Erase Log Options