32 PCI-1713 User's Manual
5.1 Introduction
Regular calibration checks are important to maintain accuracy in data
acquisition and control applications. To assist users in the A/D
calibration process, we provide one calibration program, ADCAL.EXE,
on the PCI-1713 software CD-ROM.
The ADCAL.EXE program makes A/D calibrations easy. It leads you
through the calibration and setup procedure with a variety of prompts
and graphic displays, showing you all of the correct settings and
adjustments. This chapter offers a brief guide to these calibration
programs.
To perform a satisfactory calibration, you need a 4
1
/
2
-digit digital
multimeter and a voltage calibrator or a stable, noise free D. C. voltage
source.
5.2 VR Assignment
There are four variable resistors (VRs) on the PCL-1713 card. They
help you to make accurate adjustments on all A/D channels. Please
refer to the following figure for VR positions.
V R 3
V R 2
V R 1
V R 4
C N 1
P
C
I-
1
7
1
3
R
E
V
.A
1
0
1
-6
T P 1
Summary of Contents for PCI-1713
Page 1: ...PCI 1713 32 channel Isolated Analog Input Card User s manual ...
Page 5: ...Chapter 1 General Information 1 1 General Information C H A P T E R ...
Page 11: ...Chapter 2 Installation 7 2 Installation C H A P T E R ...
Page 14: ...1 0 PCI 1713 User s Manual ...
Page 15: ...Chapter 3 Signal Connections 11 3 Signal Connections C H A P T E R ...
Page 23: ...Chapter 4 Register Structure and Format 19 4 Register Structure and Format C H A P T E R ...
Page 34: ...30 PCI 1713 User s Manual ...
Page 35: ...Chapter 5 Calibration 31 5 Calibration C H A P T E R ...
Page 39: ...Appendix A 8524 Counter Chip Functions 35 A 82C54 Counter Chip Functions A P P E N D I X ...
Page 54: ...50 PCI 1713 User s Manual ...