iDAQ-731_751_763D User Manual
38
Response time
–
Turn-on time:
1.0 ms typ./1.3 ms max.
–
Turn-off time:
0.6 ms typ./0.8 ms max.
Isolation protection:
600 V
RMS
Power-on output state:
OFF state
Acquisition type:
Static or buffered, software configurable
Buffered output
–
Update rate:
500 Hz max., software configurable
–
Internal data buffer (FIFO) size:
512 samples, each sample contains state
of all channels
A.6
General
Power consumption from chassis:
iDAQ-731:
425 mW typ./ 450 mW max.
iDAQ-751:
1050 mW typ./ 1500 mW max.
iDAQ-763D:
225 mW typ./ 800 mW max.
Module dimensions:
100 x 80 x 25 mm (3.94 x 3.15 x 0.98 in.)
Operating temperature:
-20 °C to 60 °C (-4 °F to 140 °F)
Storage temperature:
-40 °C to 70 °C (-40 °F to 158 °F)
Operating humidity:
10% to 90% RH, non-condensing
Storage humidity:
5% to 95% RH, non-condensing
Summary of Contents for iDAQ-731
Page 1: ...User Manual iDAQ 731 iDAQ 751 iDAQ 763D Digital I O and Relay Industrial DAQ Modules ...
Page 8: ...iDAQ 731_751_763D User Manual viii ...
Page 11: ...Chapter 1 1 Start Using IDAQ 731 751 763D ...
Page 16: ...iDAQ 731_751_763D User Manual 6 ...
Page 17: ...Chapter 2 2 Installation and Field Application ...
Page 28: ...iDAQ 731_751_763D User Manual 18 ...
Page 29: ...Chapter 3 3 Function Details ...
Page 42: ...iDAQ 731_751_763D User Manual 32 Figure 3 27 Streaming generation with retrigger ...
Page 44: ...iDAQ 731_751_763D User Manual 34 ...
Page 45: ...Appendix A A Specifications ...
Page 50: ...iDAQ 731_751_763D User Manual 40 ...
Page 51: ...Appendix B B System Dimensions ...
Page 52: ...iDAQ 731_751_763D User Manual 42 B 1 iDAQ Modules ...
Page 53: ...43 iDAQ 731_751_763D User Manual Appendix B System Dimensions ...