44
EKI-5729PI & EKI-5624PI User Manual
4.2
Modbus/TCP Mapping
The data map addresses of Advantech switches shown in the following table start
from Modbus address 30001 for function code 4.
In the given example, the address offset 0x1000 (hex) equals Modbus address
34097, while the address offset 0x1100 (hex) equals Modbus address 34353.
The information given by the Advantech is shown in hex mode.
4.2.1 Modbus/TCP Mapping Table
Catelog Name
Data Type
Interpr
etation
Address
Offset
(Hex)
Address
3X
Description
System
Info
Vendor ID
= 0x‘13FE
1 word
16 bits
HEX
0x0000
30001
Vendor ID = 0x13FE
Unit ID =
0xFF
1 word
16 bits
HEX
0x0001
30002
Unit ID = 0xFF
Product
Code
1 word
16 bits
HEX
0x0002
30003
Product Code
Vendor
Name =
"Advan-
tech"
16
words
32
chars
ASCII
0x0010
30017
Vendor Name =
"Advantech"
Word 0 Hi byte = 'A'
Word 0 Lo byte = 'd'
Word 1 Hi byte = 'v'
Word 1 Lo byte = 'a'
Word 2 Hi byte = 'n'
Word 2 Lo byte = 't'
Word 3 Hi byte = 'e'
Word 3 Lo byte = 'c'
Word 4 Hi byte = 'h'
Word 4 Lo byte = '\0'
Product
Name =
"EKI-xxxx"
16
words
32
chars
ASCII
0x0020
30033
Product Name = "EKI-
xxxx"
Word 0 Hi byte = 'E'
Word 0 Lo byte = 'K'
Word 1 Hi byte = 'I'
Word 1 Lo byte = '-'
Word 2 Hi byte = 'x'
Word 2 Lo byte = 'x'
Word 3 Hi byte = 'x'
Word 3 Lo byte = 'x'
Word 4 Hi byte = '\0'