Optional equipment
DLT-V72 Operating Instructions V2.50 Preliminary
119 / 140
15.1.1. Battery pack specifications
Two battery pack types are available:
Lithium-ion battery pack I
Bridging time
The integrated UPS can bridge an interruption of the main
supply for typically 20 minutes. Requirement: The battery pack
is fully charged.
Operating temperature
-20 to +40 °C
Charging time
4 h (fully recharge a completely discharged battery pack)
Charging temperature
-10 to +30 °C (ambient temperature)
Storage temperature
-20 to +60 °C
Maximum output power
40 W
Battery voltage
7,2 V
Battery capacity
2500 mAh
Lithium-ion battery pack II
Bridging time
The integrated UPS can bridge an interruption of the main
supply for typically 20 minutes. Requirement: The battery pack
is fully charged.
Operating temperature
-30 to +50 °C
Charging time
4 h (fully recharge a completely discharged battery pack).
Charging temperature
-10 to +50 °C (ambient temperature)
Storage temperature
-30 to +60 °C
Maximum output power
40 W
Battery voltage
7,2 V
Battery capacity
2000 mAh