Capacity
4
HP
Type
5
HP
GPM
PSI
Process (to/from)
Make-Up
Condenser Type
6
Motor Quantity
Motor HP
CFM x 1000
S.P.
7
230 volt
460 volt
575 volt
Type
Holding
Height
Width
Depth
Shipping
8
MAXIMUM 'MK-A' SPECIFICATIONS
COMPRESSOR
PROCESS PUMPS
1
CONNECTION SIZES
(inches NPT)
AIR-COOLED
CONDENSER
FULL LOAD
2
AMPERAGE@3ø/60hz
3
REFRIGERANT (HCFC)
TANK CAPACITY
(gallons)
DIMENSIONS
(inches)
WEIGHTS
(pounds)
5A
5
5
H
2
12
52
1
1
/
4
1
/
2
F
1
3
/
4
5
n/a
30
15
12
22
25
60
34
40
700
7.5A
7
1
/
2
7
1
/
2
H
2
18
50
1
1
/
4
1
/
2
F
2
3
/
4
10
n/a
45
23
19
22
25
60
34
56
1,250
10A
10
10
H
2
24
48
1
1
/
4
1
/
2
F
2
3
/
4
10
n/a
52
26
21
22
25
60
34
56
1,300
15A
15
15
H
3
36
58
1
1
/
2
1
/
2
B
1
7
1
/
2
15
1.35
90
45
36
22
65
96
58
70
1,790
15A
15
15
H
3
36
58
1
1
/
2
1
/
2
F
1
3
15
n/a
74
37
30
22
65
96
58
70
1,790
20A
20
(2)10
H
3
48
55
1
1
/
2
1
/
2
B
1
10
20
1.35
114
57
46
22
65
96
58
70
2,100
20A
20
(2)10
H
3
48
55
1
1
/
2
1
/
2
F
1
5
20
n/a
102
51
41
22
65
96
58
70
2,100
25A
25
(2)13
H
5
60
59
2
1
/
2
B
1
15
25
1.35
158
79
64
22
65
96
58
70
2,300
30A
30
(2)15
H
5
72
57
2
1
/
2
B
1
20
30
1.35
178
89
72
22
65
96
58
70
2,400
1.
Refer to FYI #3-C-36 for exact characteristics relating to pump curves.
2.
Full load amps are higher than run load amps and must
be used for sizing disconnects and supply wiring.
3.
Consult factory for 50hz operation.
4.
Tons capacity at 12,000 BTU/ton @ 50
°
F
LWT @ 115
°
F condensing temperature. Capacities may be +/- 5% as reserved by the compressor manufacturer. Capacity multipliers
are 50
°
F - 1.00; 40
°
F -.80; 30
°
F -.60; 20
°
F - .40. The minimum recommended operating temperature when no glycol is used is 48
°
F.
5.
H - hermetic scroll compressor used on this model.
6.
F - fan type; B - blower type.
7.
Static pressure in inches of water.
8.
Approximate unit weight crated for shipment.
8.1
SPECIFICATIONS
Summary of Contents for Maximum
Page 2: ......
Page 6: ...Page 6 THIS PAGE INTENTIONALLY BLANK ...
Page 44: ...Page 44 THIS PAGE INTENTIONALLY BLANK ...
Page 58: ...Page 58 THIS PAGE INTENTIONALLY BLANK ...
Page 79: ...END 2003 ADVANTAGE ENGINEERING INC RE 1 2 03 ...
Page 80: ......