Page 22 of 26
Advanjet HV-9500 Maintenance and Repair
3A5910A
3.6
Reassemble the Jet (Continued)
3.6.5
Attach the Mounting Plate
Position the heater block cables so they
pass through the mounting plate groove.
Use the alignment pins to position the
mounting plate. Check that the cables are
not pinched.
Apply Loctite 243 to the tips of the screws
and attach to the jet back (3mm).
3.6.6
Attach the Solenoid Connector
If the solenoid connector was removed, use a #1PH
to install as shown. Do not over-tighten the screws.
3.6.7
Attach the Dovetail Plate and
Syringe Holder
Apply Loctite 243 to the tips of the four dovetail
plate screws and attach to the mounting plate
(3mm). Flip jet over. Apply Loctite 243 to the
tips of the two syringe holder screws and attach
to the jet front (3mm).
3.6.8
(Optional) Attach the Feed Tube
Enclosure
AFTER the jet hammer
gap has been set:
Apply Loctite 243 to the
tips of the two upper
feed
tube
enclosure
screws and attach to the
heater block (2.5mm).
AFTER the feed tube
has been installed:
Position the lower feed
tube
enclosure
and
tighten the thumbscrew
to attach.
Continue to the next section
—Set the Jet Hammer Gap.
OVER-
TIGHTENING
CAN EASILY
BREAK THIS
PLASTIC