3.4
Attach Heater Block
3.4.1
Heater Block and Cable
3.4.1a
BK-2001 (Existing Heater Block)
Locate the existing heater block and screws.
3.4.1b
HK-9500 (New Heater Block)
Connect the heater cable assembly of the new
heater block to the jet cable.
3.4.2
Position the Heater Block
Align the pins in the heater block with the heater
seal as shown below.
3.4.3
Attach the Heater Block
Apply Loctite 243 to the tips of the two heater
block screws and attach the heater block (#1PH).