1.2  Cautions and Warnings 

S T O P

 

BEFORE INSTALLATION – Refer To the Ratings shown on the label inside 
the product and to the ‘Specifications Chart’ in this document. 
Please read this manual carefully. If you are unclear on any point DO NOT 
proceed. Contact the manufacturer or supplier for clarification and guidance.  

 

 

 

Only Trained service personnel should undertake the Installation, 
Programming and Maintenance of this equipment. 
 

 

This product has been designed to comply with the requirements of the Low 
Voltage Safety and the EMC Directives. Failure to follow the installation 
instructions may compromise its adherence to these standards. 

 

 

A T T E N T IO N  

O B S E R V E  P R E C A U T IO N S  

F O R  H A N D L IN G  

E L E C T R O S T A T IC  

S E N S IT IV E  D E V IC E S  

 

This equipment is constructed with static sensitive components. Observe anti-
static precautions at all times when handling printed circuit boards.  Wear an 
anti-static earth strap connected to panel enclosure earth point. Before installing 
or removing any printed circuit boards remove all sources of power (mains and 
battery).  

1.3  Description 

The 5000R Series is a modular assembly rack mount version of the 5000 Series of Fire Alarm Control panels. 
The panels and peripheral devices are housed in dedicated module assemblies designed to be installed into 
standard 19” rack mount enclosures.  

Enclosures are provided in different sizes to IP55 rating (IP30 with outer glass door open). In addition, the 
module assemblies can be mounted into commercial rack mount enclosures. 

This manual covers the installation of the rack mount 

5000R, 5000VR Series

 Fire Alarm Control Panel 

assemblies and enclosures only. For all other information: 

Refer to Product Manual (Document No. 680-165) for all other information on installation and programming 
of the panel. 

Refer to the User Manual (Document No. 680-166) for details of how to operate the panel. 

Refer to the appropriate protocol application note for further and specific information for each protocol. 

Refer to individual power supply module, peripheral bus module or network peripheral module 
documentation for detailed information on these items. 

1.3.1  5000R Series 

The 

5100R

 is a Single Loop, Analogue Addressable Fire Alarm Control Panel. 

The 

5200R

 is a Two Loop, Analogue Addressable Fire Alarm Control Panel. 

The 

5400R

 is a Multiple Loop, Analogue Addressable Fire Alarm Control Panel with provision for up to four 

loops.  

All above models are designed for use with the Apollo (Discovery, Explorer, XP95 and Series 90) and Hochiki 
(ESP). 

1.3.2  5000VR Series 

The 

5100VR

 is a Single Loop, Analogue Addressable Fire Alarm Control Panel. 

The 

5200VR

 is a Two Loop, Analogue Addressable Fire Alarm Control Panel. 

The 

5400VR

 is a Multiple Loop, Analogue Addressable Fire Alarm Control Panel with provision for up to four 

loops.  

All above models are designed for use with the Advanced (AV) fire detection devices. 

1.4  EN54 Functions 

The EN54 functions and options with requirements are identical to standard 5000 Series Panels. Refer to the 
Product Manual (Document No. 680-165) for information. 

Summary of Contents for Mx-5101xR

Page 1: ...www advancedco com 5000 Series Rack Panels The operation and functions described in this manual are available from Software Version Mx5000 050 04 onwards...

Page 2: ...Door with LED Aperture Mxm 513 D3 Enclosure Utility Module 6U Door with Aperture Mxm 513 FP Enclosure Utility Module 6U Fascia Plate Blank Mxm 513 MF Enclosure Utility Module 6U Switch LED Mounting F...

Page 3: ...ECHANICAL SPECIFICATIONS 8 2 2 1 Enclosure 16U 8 2 2 2 Enclosure Other Sizes 9 2 2 3 Enclosure Commercial 9 2 2 4 Battery Gas Venting 9 2 2 5 Battery Shelf Chassis Plate DIN Rail 9 2 2 5 1 MXM 510 BS...

Page 4: ...put to Fault Routing Equipment Investigation Delays to Outputs Dependency on more than one alarm signal Fault Signals from Points Disablement of Points Alarm Counter Test Condition Standardised Input...

Page 5: ...ddition the module assemblies can be mounted into commercial rack mount enclosures This manual covers the installation of the rack mount 5000R 5000VR Series Fire Alarm Control Panel assemblies and enc...

Page 6: ...code of practice or national standard regulations for fire systems installation for example BS5839 1 2002 appropriate to the country and location of the installation 1 5 2 Wiring Regulations The panel...

Page 7: ...l model refer the separate sections in this manual Visual indicators can be seen through the glass panel The outer door is not locked to provide access to Level 1 and Level 2 controls An optional key...

Page 8: ...re and can be fitted behind Zone LED modules or blanking plates Mount the enclosure on the wall using fixing hardware suitable for the size and weight of the complete enclosure 2 The fixing holes are...

Page 9: ...le for the IP rating required 2 2 5 Battery Shelf Chassis Plate DIN Rail 2 2 5 1 MXM 510 BS Up to two battery shelves can be fitted for mounting of 7Ah or 18Ah batteries The shelves rest on the side w...

Page 10: ...her two peripheral bus modules Screw these M3 pillars into the captive nuts on the chassis plate and then mount and affix the modules using the M3 screws supplied with the module The PSE module fits d...

Page 11: ...ox is 125 mm The panel module weight is 6 kg The door is securely locked using the standard Advanced Electronics Ltd panel key The internal arrangement of the panel module is shown in the following di...

Page 12: ...Keep the AC wiring away from the circuit boards and all other wiring The mains input connector is shown in the diagram below Note the positions of the earth neutral and live terminal connections These...

Page 13: ...e battery leads Use the supplied tie wraps to tie the sensor cable to the battery leads so that the encapsulated sensor is located close to the batteries The sensor cable is 500mm in length NOTE If th...

Page 14: ...unting frame using 4x M4 Nuts and washers Connect the ribbon cable to the display card Route the cable through the lower hole in the left hand side of the panel module enclosure and connect to the inp...

Page 15: ...be fitted 2 3 3 1 Chassis The utility chassis plate can accept the following module types 1x PSE Module Mxs 049 Mxs 050 or Mxs 051 and 1x Mxp 510 BMS Interface4 or 1x Mxp 554 ipGateway or 2x standard...

Page 16: ...the Mxs 049 to the upper four holes and fit the Mxs 050 and Mxs 051 to the outer four holes Fit the terminal block to the enclosure using the two supplied M3 Screws and affix the integral earth lead t...

Page 17: ...r hole in the left hand side of the panel module enclosure Route the cable through the lower hole in the left hand side of the utility module enclosure and connect to the input connector top of the fi...

Page 18: ...e can be drilled and screen printing for the required graphic indicator diagram Mimic area 350 W x 180 H Up to two Mxp 539 Input Output Cards are required to be mounted to the chassis LED and Switch o...

Page 19: ...blank plate in the door can be removed so that it can be drilled and screen printed as required for fitting of switches and LED indicators 2 3 4 1 Chassis 6U The 6U Chassis can be fitted refer to pre...

Page 20: ...051 and Up to 4x Mxp 539 Mimic Interface Modules Up to 192 LED and up to 64 Switches 5 Mxp 020 and Mxp 045 modules can also be fitted in this one location An additional Mxs 027 can be also be fitted...

Page 21: ...es and fit the Mxs 050 and Mxs 051 to the outer four holes Fit the terminal block to the enclosure using the two supplied M3 Screws and affix the integral earth lead to the stud using the supplied M4...

Page 22: ...he enclosure Ensure the leads are tie wrapped securely to the module enclosure next to the terminal block Item Specification Details AC Supply Voltage 200 240V 47 63Hz AC 6 AC Supply Current Maximum 4...

Page 23: ...www advancedco com USER NOTES...

Page 24: ...nced Electronics Ltd Moorland Way Cramlington Northumberland NE23 1WE UK Tel 44 0 1670 707 111 Fax 44 0 1670 707 222 Email sales advancedco com Web www advancedco com Doc Number 680 195 Revision 01A F...

Reviews: