2.3.1.1.2  Battery 

The batteries must be located on the battery shelf behind the module or in the bottom of the enclosure. Fit the 
Mxp-501 Battery Remote Temperature Sensor to ensure that the batteries are charged at the correct voltage. 

Plug the Mxp-501 into the connector and route the sensor cable along with the battery leads. Use the supplied 
tie-wraps to tie the sensor cable to the battery leads so that the encapsulated sensor is located close to the 
batteries. The sensor cable is 500mm in length. 

 

NOTE: If the base card is not fitted with either a jumper or a remote temperature sensor the panel will indicate a 
charger failure condition. Ensure that the jumper is replaced if the remote sensor is removed / not used. 

 

 

W A R N IN G : 

H IG H  V O L T A G E  IN S ID E

D O  N O T  R E M O V E  C O V E R

N o  S e rv ic e a b le  P a rts  In s id e

Jumper 

– centre two pins 

Battery Leads 

Sensor 

Summary of Contents for Mx-5101xR

Page 1: ...www advancedco com 5000 Series Rack Panels The operation and functions described in this manual are available from Software Version Mx5000 050 04 onwards...

Page 2: ...Door with LED Aperture Mxm 513 D3 Enclosure Utility Module 6U Door with Aperture Mxm 513 FP Enclosure Utility Module 6U Fascia Plate Blank Mxm 513 MF Enclosure Utility Module 6U Switch LED Mounting F...

Page 3: ...ECHANICAL SPECIFICATIONS 8 2 2 1 Enclosure 16U 8 2 2 2 Enclosure Other Sizes 9 2 2 3 Enclosure Commercial 9 2 2 4 Battery Gas Venting 9 2 2 5 Battery Shelf Chassis Plate DIN Rail 9 2 2 5 1 MXM 510 BS...

Page 4: ...put to Fault Routing Equipment Investigation Delays to Outputs Dependency on more than one alarm signal Fault Signals from Points Disablement of Points Alarm Counter Test Condition Standardised Input...

Page 5: ...ddition the module assemblies can be mounted into commercial rack mount enclosures This manual covers the installation of the rack mount 5000R 5000VR Series Fire Alarm Control Panel assemblies and enc...

Page 6: ...code of practice or national standard regulations for fire systems installation for example BS5839 1 2002 appropriate to the country and location of the installation 1 5 2 Wiring Regulations The panel...

Page 7: ...l model refer the separate sections in this manual Visual indicators can be seen through the glass panel The outer door is not locked to provide access to Level 1 and Level 2 controls An optional key...

Page 8: ...re and can be fitted behind Zone LED modules or blanking plates Mount the enclosure on the wall using fixing hardware suitable for the size and weight of the complete enclosure 2 The fixing holes are...

Page 9: ...le for the IP rating required 2 2 5 Battery Shelf Chassis Plate DIN Rail 2 2 5 1 MXM 510 BS Up to two battery shelves can be fitted for mounting of 7Ah or 18Ah batteries The shelves rest on the side w...

Page 10: ...her two peripheral bus modules Screw these M3 pillars into the captive nuts on the chassis plate and then mount and affix the modules using the M3 screws supplied with the module The PSE module fits d...

Page 11: ...ox is 125 mm The panel module weight is 6 kg The door is securely locked using the standard Advanced Electronics Ltd panel key The internal arrangement of the panel module is shown in the following di...

Page 12: ...Keep the AC wiring away from the circuit boards and all other wiring The mains input connector is shown in the diagram below Note the positions of the earth neutral and live terminal connections These...

Page 13: ...e battery leads Use the supplied tie wraps to tie the sensor cable to the battery leads so that the encapsulated sensor is located close to the batteries The sensor cable is 500mm in length NOTE If th...

Page 14: ...unting frame using 4x M4 Nuts and washers Connect the ribbon cable to the display card Route the cable through the lower hole in the left hand side of the panel module enclosure and connect to the inp...

Page 15: ...be fitted 2 3 3 1 Chassis The utility chassis plate can accept the following module types 1x PSE Module Mxs 049 Mxs 050 or Mxs 051 and 1x Mxp 510 BMS Interface4 or 1x Mxp 554 ipGateway or 2x standard...

Page 16: ...the Mxs 049 to the upper four holes and fit the Mxs 050 and Mxs 051 to the outer four holes Fit the terminal block to the enclosure using the two supplied M3 Screws and affix the integral earth lead t...

Page 17: ...r hole in the left hand side of the panel module enclosure Route the cable through the lower hole in the left hand side of the utility module enclosure and connect to the input connector top of the fi...

Page 18: ...e can be drilled and screen printing for the required graphic indicator diagram Mimic area 350 W x 180 H Up to two Mxp 539 Input Output Cards are required to be mounted to the chassis LED and Switch o...

Page 19: ...blank plate in the door can be removed so that it can be drilled and screen printed as required for fitting of switches and LED indicators 2 3 4 1 Chassis 6U The 6U Chassis can be fitted refer to pre...

Page 20: ...051 and Up to 4x Mxp 539 Mimic Interface Modules Up to 192 LED and up to 64 Switches 5 Mxp 020 and Mxp 045 modules can also be fitted in this one location An additional Mxs 027 can be also be fitted...

Page 21: ...es and fit the Mxs 050 and Mxs 051 to the outer four holes Fit the terminal block to the enclosure using the two supplied M3 Screws and affix the integral earth lead to the stud using the supplied M4...

Page 22: ...he enclosure Ensure the leads are tie wrapped securely to the module enclosure next to the terminal block Item Specification Details AC Supply Voltage 200 240V 47 63Hz AC 6 AC Supply Current Maximum 4...

Page 23: ...www advancedco com USER NOTES...

Page 24: ...nced Electronics Ltd Moorland Way Cramlington Northumberland NE23 1WE UK Tel 44 0 1670 707 111 Fax 44 0 1670 707 222 Email sales advancedco com Web www advancedco com Doc Number 680 195 Revision 01A F...

Reviews: