ACT4 Electrofusion Welding Unit – Operator Manual – Rev: 4.1.G
© 2008. Advance Welding.
Page 8
Delivered Items
Carefully remove the welding unit from its packaging and check that
you have the following items:
Welding unit.
Welding cable.
USB flash memory drive.
When parts are missing or damaged, please contact your dealer.
Electrical Safety
WARNING! Switch off and remove the plug from the mains before
adjusting, cleaning or if the cable is cut, damaged or entangled.
This welding unit is Class 1 and requires an earthed (grounded)
connection. An earth spike must be used with generators.
This unit is 110 volt operation.
The power source must be capable of providing 6930 Watts.
This equipment must be fitted with a 63 amp mains plug.
Extension cables should only be used if they comply with the
H07RNF harmonized standard. They must be fitted with connectors
to the BS EN 60309-2 standard. All cables must be unwound from
the reel to stop inductive heating effects. Only use one 10m
extension cable with a conductor size 4.0mm
2
.
This equipment is fitted with a Residual Current Device (RCD) with
a tripping current of 30 mA. Always check the RCD every time you
use it.
The supply cable must be inspected for signs of damage before
each use and the equipment may only be used if in perfect
condition. Damaged cables must be replaced by an approved
service agent.
This equipment is classified as “Portable for use on industrial
applications
”, and must undergo a formal electrical safety check
(Portable Appliance Test) as per local regulations.