Data Log Memory (Optional)
The unit can record information about the weld, along with the date
and time, and additional operator entered information.
It is possible to enter three pieces of information to identify the weld.
The first is the Operator’s Name, the second is the Location where
the weld is being done, and the third is an Information field for more
details.
The display will show all three pieces of information:
Pressing the B Quick-
key will select the ‘Operator Name’ and allow
changes to be made. Enter the required information and press the
A Quick-key to accept it.
Pressing the C Quick-
key will select the ‘Location’ and allow
changes to be made. Enter the required information and press the
A Quick-key to accept it.
Pressing the D Quick-key will select th
e ‘Information Field’ and
allow changes to be made. Enter the required information and press
the A Quick-key to accept it.
When all the information has been entered, press the A Quick-key
to accept it.
This information will be saved when the weld has been completed,
and will be prompted the next time a new weld is carried out.
The display will also ask if the pipe/fitting has been scraped and
clamped. Select yes or no using the Quick-Keys. This information
will be saved on the data log memory.
The unit can save 2048 welds in memory. When the memory is full,
it will be overwritten from the beginning in blocks of 24 welds. This
will allow the last 2000 welds to be held in memory.
An optional “lifetime weld memory” feature is available. This uses
an SD memory card fitted internally that records every weld carried
out by the unit. This is designed as a backup device and can only
be downloaded by an approved service agent.