12
- FORM NO. 56043111 - Adhancer
™
KNOW YOUR MACHINE
DESCRIPTION OF INDICATORS ON THE CONTROL PANEL:
In general, the following guidelines apply to the control panel indicators:
A
fl
ashing red or yellow
indicator means that a fault has occurred in the particular system. An example of this would be an over-current fault.
A
yellow
indicator means that the particular function has been enabled but is not currently on. For example, if a scrub mode is selected and the
throttle is in neutral, the scrub system, vacuum and solution indicators will all be yellow indicating that the systems are enabled and ready to turn on
when the throttle is moved to forward or reverse.
A
green
indicator means that the particular system is on.
A
fl
ashing green
indicator means that the particular system is in a delayed-off condition. An example of this is when a scrub mode is selected and
the throttle goes from forward or reverse to neutral. When this happens, the Vacuum System Indicator
(N)
will
fl
ash green indicating that the vacuum
is still on but will be switching off after a 10-second delay.
Scrub Off Indicator (J):
This indicator will be green when the scrub system is off and the scrub deck is up in its retracted position.
This indicator will be off when the scrub system has been switched on, the scrub deck is either moving downward or in its extended (scrub)
position, but the drive paddle is in neutral and the machine is not moving.
This indicator will be red when the scrub system has been switched off and the scrub deck is moving upward toward the retracted position.
This indicator will
fl
ash red if there is a fault in the scrub system.
Scrub On Indicators (K and L):
These indicators will be off when the scrub system is switched off and scrub deck is up in its retracted position.
These indicators will be yellow when the scrub system is switched on and the scrub deck is either moving downward or in its extended (scrub)
position, but the drive paddle is in neutral and the machine is not moving.
These indicators will be green when the scrub motors are running and the machine is moving in either direction.
Control panel Display (D):
See the detailed drawing shown in the
Know Your Machine
manual section for the speci
fi
c description of the individual icon symbols.
Wand Switch Indicator (M):
This indicator will be off when the Wand Switch has been turned Off.
This indicator will be green when the Wand Switch has been turned On.
Note:
If a speed control fault occurs (error code 03), the Wand Indicator
(M)
will
fl
ash the fault code produced by the Curtis speed control. Refer to
the
Electrical System/Troubleshooting Guide
section for details.
Detergent “AXP” System Indicator (P):
This indicator will be green when the AXP system is on.
This indicator will be yellow when the AXP system is enabled but the drive paddle is in neutral.
This indicator will be off when the AXP system is disabled and turned off.
Recycle/Extended Scrub Switch Indicator (G)
: Not used. The recycle/extended scrub system is not available on the Adhancer.
Vacuum System Indicator (N):
This indicator will be green when the vacuum is on.
This indicator will
fl
ash green when the vacuum is in the 10-second delayed-off condition.
This indicator will be yellow when the vacuum is enabled but the drive pedal is in neutral.
This indicator will
fl
ash yellow when there is a vacuum system fault.
This indicator will be off when the vacuum is disabled and switched off.
Solution System Indicator (O):
This indicator will be green when the solution system is on.
This indicator will be yellow when the solution is enabled but the drive paddle is in neutral.
This indicator will
fl
ash yellow when there is a solution system fault.
This indicator will be off when the solution system is disabled and turned off.
Summary of Contents for Adhancer 56316001(W32-C)
Page 1: ...7 08 FORM NO 56043111 SERVICE MANUAL Models 56316000 W28 C 56316001 W32 C Adhancer...
Page 2: ......
Page 7: ...FORM NO 56043111 Adhancer 5 TECHNICAL SPECIFICATIONS...
Page 25: ...FORM NO 56043111 Adhancer 23 SCRUB SYSTEM FIGURE 2...
Page 51: ...FORM NO 56043111 Adhancer 49 FIGURE 4...
Page 53: ...FORM NO 56043111 Adhancer 51 FIGURE 5 ELECTRICAL SYSTEM...
Page 59: ...FORM NO 56043111 Adhancer 57 FIGURE 6 ELECTRICAL SYSTEM...
Page 68: ......