This section provides instructions for configuring a pair of
ADTRAN NetVanta 2730 appliances for High Availability (HA).
This section is relevant to administrators following deployment
Scenario B
.
Note:
High Availability is supported for two ADTRAN
NetVanta 2730 appliances of the same model.
This section contains the following subsections:
•
•
•
Configuring Advanced High Availability Settings
•
•
Configuring HA License Overview
•
Associating Pre-Registered Appliances
Initial HA Setup
Before you begin the configuration of HA on the Primary
ADTRAN security appliance, perform the following setup:
1.
On the back panel of the Backup ADTRAN security
appliance, locate the serial number and write the number
down. You need to enter this number in the
High
Availability
>
Settings
page.
2.
Verify that the Primary appliance and Backup ADTRAN
security appliances are registered and running the same
ADTRAN Security services.
3.
Make sure the Primary appliance and Backup ADTRAN
security appliances’ LAN, WAN and other interfaces are
properly configured for failover.
4.
Connect the X8 ports on the Primary appliance and Backup
ADTRAN appliances with a CAT 5 Ethernet cable. The
Primary and Backup security appliances must have a
dedicated connection.
5.
Power up the Primary ADTRAN security appliance, and
then power up the Backup ADTRAN security appliance.
6.
Do not make any configuration changes to the Primary’s
X8; the High Availability configuration in an upcoming step
takes care of this issue.