ADTECH4 SeriesCNC Maintenance Manual
Authority
:
Operation admin
Default
:
24000
Effective time
:
Instant
Note
:
Set the maximum speed of second channel principal axis
035
Second channel principal axis speed
Range
:
1 ~ 24000
Unit
:
rpm
Authority
:
Operation admin
Default
:
6000
Effective time
:
Instant
Note
:
Set the speed of second channel principal axis
036
Principal axis command S value invalid enable
Range
:
OFF ON
Unit
:
Authority
:
Operation admin
Default
:
OFF
Effective time
:
Instant
Note
:
When set to ON, the value specified by S in M03Sxxxx instruction is
invalid, and the principal axis speed uses the value specified by P5.031.
037
Mechanical principal axis first gear speed (L series)
038
Mechanical principal axis second gear speed (L series)
039
Mechanical principal axis third gear speed (L series)
040
Mechanical principal axis fourth gear speed (L series)
Range
:
1~1000000
Unit
:
rpm
Authority
:
Operation admin
Default
:
24000
Effective time
:
Instant
Note
:
This parameter is used for L version system of lathe, to the maximum
Summary of Contents for ADTECH4 CNC Series
Page 1: ...ADTECH4 Series CNC Maintenance Manual ...
Page 51: ...ADTECH4 SeriesCNC Maintenance Manual Absolute Position Interface ...
Page 132: ...ADTECH4 SeriesCNC Maintenance Manual ...
Page 157: ...ADTECH4 SeriesCNC Maintenance Manual 12 1 3 46 Series Mounting dimensions ...
Page 158: ...ADTECH4 SeriesCNC Maintenance Manual 12 1 4 49 Series Mounting dimensions ...
Page 176: ...ADTECH4 SeriesCNC Maintenance Manual 25 OUTGND12V 24V common power supply of external output ...
Page 188: ...ADTECH4 SeriesCNC Maintenance Manual 12 3 2 Power connection diagram ...
Page 189: ...ADTECH4 SeriesCNC Maintenance Manual 12 3 3 Servo drive connection diagram ...
Page 190: ...ADTECH4 SeriesCNC Maintenance Manual 12 3 4 Step connection diagram ...
Page 191: ...ADTECH4 SeriesCNC Maintenance Manual 12 3 5 IO electrical connection diagram ...
Page 192: ...ADTECH4 SeriesCNC Maintenance Manual ...