ADTECH4 SeriesCNC Maintenance Manual
Effective time
:
Restart
Note
:
Set pulse direction; if the controller direction is reverse to actual drive
direction, please modify this parameter to adjust the rotation direction of
motor.
020
Effective voltage level for X external home
Effective voltage level for Y external home
Effective voltage level for Z external home
Effective voltage level for 4 external home
Effective voltage level for B external home
Effective voltage level for C external home
Range
:
0~1
Unit
:
LOGIC VOLTAGE LEVEL
Authority
:
Super admin
Default
:
0
Effective time
:
Instant
Note
:
Set the effective voltage level of external home sensor switch during
home operation.
Low level
High level
021
X axis ROUND settings (restart)
Y axis ROUND settings (restart)
Z axis ROUND settings (restart)
4 axes ROUND settings (restart)
B axis ROUND settings (restart)
C axis ROUND settings (restart)
Range
:
0~9999999
Unit
:
Pulse
Authority
:
Super admin
Default
:
0
Effective time
:
Restart
Note
:
Round function is available on hardware version 1.0 or later only;
Summary of Contents for ADTECH4 CNC Series
Page 1: ...ADTECH4 Series CNC Maintenance Manual ...
Page 51: ...ADTECH4 SeriesCNC Maintenance Manual Absolute Position Interface ...
Page 132: ...ADTECH4 SeriesCNC Maintenance Manual ...
Page 157: ...ADTECH4 SeriesCNC Maintenance Manual 12 1 3 46 Series Mounting dimensions ...
Page 158: ...ADTECH4 SeriesCNC Maintenance Manual 12 1 4 49 Series Mounting dimensions ...
Page 176: ...ADTECH4 SeriesCNC Maintenance Manual 25 OUTGND12V 24V common power supply of external output ...
Page 188: ...ADTECH4 SeriesCNC Maintenance Manual 12 3 2 Power connection diagram ...
Page 189: ...ADTECH4 SeriesCNC Maintenance Manual 12 3 3 Servo drive connection diagram ...
Page 190: ...ADTECH4 SeriesCNC Maintenance Manual 12 3 4 Step connection diagram ...
Page 191: ...ADTECH4 SeriesCNC Maintenance Manual 12 3 5 IO electrical connection diagram ...
Page 192: ...ADTECH4 SeriesCNC Maintenance Manual ...