ADTECH4 SeriesCNC Maintenance Manual
029
Inp AccSpeed Mode (1: linear acceleration/deceleration 0:S curve acceleration/deceleration)
030
'S' Speed Acceleration
Range
:
Unit
:
Authority
:
Operation admin
Default
:
Effective time
:
Instant
Note
:
Used to set the performance of S curve acceleration/deceleration
031
Home test enable after alarm
032
System home test enable
Range
:
0~1
Unit
:
Authority
:
Operation admin
Default
:
0, 1
Effective time
:
Instant
Note
:
Used to set whether prompt user to home in corresponding occasions,
ensuring that the user has performed the home operation;
If it is set to 0, the system will run directly without performing home
operation.
033
X axis diameter programming enable (L series)
Range
:
0~1
Unit
:
Authority
:
Operation admin
Default
:
1 (L series)/0 (M series)
Effective time
:
Instant
Note
:
On lathe controller (L series), it is used to set whether the display and
programming of X axis are in radius or diameter;
034
Default process plane
Range
:
G17,18,19
Summary of Contents for ADTECH4 CNC Series
Page 1: ...ADTECH4 Series CNC Maintenance Manual ...
Page 51: ...ADTECH4 SeriesCNC Maintenance Manual Absolute Position Interface ...
Page 132: ...ADTECH4 SeriesCNC Maintenance Manual ...
Page 157: ...ADTECH4 SeriesCNC Maintenance Manual 12 1 3 46 Series Mounting dimensions ...
Page 158: ...ADTECH4 SeriesCNC Maintenance Manual 12 1 4 49 Series Mounting dimensions ...
Page 176: ...ADTECH4 SeriesCNC Maintenance Manual 25 OUTGND12V 24V common power supply of external output ...
Page 188: ...ADTECH4 SeriesCNC Maintenance Manual 12 3 2 Power connection diagram ...
Page 189: ...ADTECH4 SeriesCNC Maintenance Manual 12 3 3 Servo drive connection diagram ...
Page 190: ...ADTECH4 SeriesCNC Maintenance Manual 12 3 4 Step connection diagram ...
Page 191: ...ADTECH4 SeriesCNC Maintenance Manual 12 3 5 IO electrical connection diagram ...
Page 192: ...ADTECH4 SeriesCNC Maintenance Manual ...