ADT-HC4500 Flame/Plasma Cutting Machine CNC System
- 114 -
2.2.5 Power connection of SX8
2.2.6 Standard USB interface of SX11
3. Motor connection
3.1 Differential drive connection
The following diagram is the controller connected to ADT Q2BYG404MA drive:
ZDR-
XDR-
5V-
ZDR+
5V-
XDR+
YDR-
XPU-
PU_COM
XS3
8
15
7
14
6
13
5
12
4
11
3
10
2
9
1
ZPU+
ZPU-
XPU+
YDR+
YPU-
YPU+
The following diagram is ADT Q2BYG404MA drive connected to 56BYGH630C step motor
Controller XS3 plug
Q2BYG404MA drive
+
PU
+
DR
+
MF
V+
V-
AC
BC
A+