Appendix
36
E - Connector Specifications
Soloist 4111HD Terminal Port
The Soloist 4111HD Terminal port is an industry standard RS232
DTE device on RJ45/RJ48. The default port settings are 115,200 baud,
8 data, 1 stop and no parity. The pinout is:
Pin
Use
1
Data Set Ready (DSR)
2
Carrier Detect (DCD)
3
Data Terminal Ready (DTR)
4
Ground (GND)
5
Receive Data (RXD)
6
Transmit Data (TXD)
7
Clear to Send (CTS)
8
Request to Send (RTS)
Soloist 4111HD RS-232 Port
The Soloist 4111HD RS-232 Port is an industry standard RS-232
DTE device on DB9, without hardware flow control. The default port
settings are 38,400 baud, 8 data, 1 stop and no parity. The pinout is:
Pin
Use
1
Not Connected (NC)
2
Receive Data (RXD)
3
Transmit Data (TXD)
4
Not Connected (NC)
5
Ground (GND)
6
Not Connected (NC)
7
Not Connected (NC)
8
Not Connected (NC)
9
Not Connected (NC)
Summary of Contents for edje 4111 HD
Page 2: ...Intentionally Left Blank ...
Page 5: ...3 ...
Page 15: ...13 Chapter 2 Player Server Installation ...
Page 17: ...15 Chapter3 mediaControl Setup Figure 3 1 ...
Page 41: ...Intentionally Left Blank ...
Page 42: ......