![ADT NVR7400 Series User Manual Download Page 80](http://html1.mh-extra.com/html/adt/nvr7400-series/nvr7400-series_user-manual_2853964080.webp)
Hybrid Standalone NVR User Guide
Sensitivity
(Motion Detection and Tampering only) The system supports 6 levels. The sixth level has the highest
sensitivity. The default setup is 3.
Period
Click the
Setup
button. The Setup dialog opens, where you can set the time period when detection is
enabled. Select
Sunday to Saturday
from the dropdown list. Be sure to check the box to the left of
the period to enable it. To set your own business day and non-business days, select work day or non-
work day from the drop down list, and then click the
Setup
button. For example, you can set Monday
to Friday as working days and Saturday and Sunday as non-working days. Click the
Save
button to
return to the previous screen.
Anti-dither
(Motion Detection only) This feature sets a delay period before triggering the next Motion Detection
event, to avoid re-triggering on the same event. The delay period begins when the current motion
detection event has ended. The system only stores one event during the anti-dither period. The value
ranges from 5s to 600s.
Alarm Out
Check the box to enable the external alarm when the event triggers. In the boxes to the immediate
right, enable which camera(s) will record when the event occurs.
Latch
Select the time in seconds that the system delays after the external alarm has ended before turning
off the alarm and the activated output. This feature sets a postponement period before another
external alarm can be activated. Value ranges from 10 to 300 seconds.
Show Message
Enable Show Message to pop up a warning message on the local monitor to alert you that the event
has occurred.
Alarm Upload
Enable this feature to upload an alarm signal to the network.
Send Email
Enable this to send out email to alert you when the event occurs.
Record Channel
The system automatically activates the designated channel(s) to record once a Motion Detection event
occurs. Make sure you have set MD Record in Schedule screen (
Main Menu > Setting > Schedule
) and
Schedule Record on the Manual Record screen (
Main Menu > Storage > Manual Record)
.
Delay
To avoid rerecording the same event, enter the number of seconds to wait after the event has ended
before a new recording can begin. This value ranges from 10s to 300s.
NVR7400 Series User Guide