– 9 –
PROMPTS
ENTRY
OPTIONS
DESCRIPTION
5
Change Password?
(Y/N)_
[Y], [N]
If a password has already been assigned, this
prompt appears after pressing [N] at the
"Program Device?" prompt.
Press [Y] if you want to change the password.
NOTE:
To clear an existing password, without
entering a new one, answer [Y] to the
"Change Password?" prompt, then press the
[Enter] key when prompted for the new
password and its confirmation.
6
Enter Password
[0-9, A-F, N,
S, T, X, Y]
This prompt is displayed if [Y] was pressed in
Prompt 4 or 5.
Enter a 4-digit password
(0-9, A-F, N, S, T, X, Y).
Re-enter the password as confirmation.
If the password doesn't match the first entry,
the following is displayed followed by the "Exit
Prog. Mode?" prompt:
7
[0-9, A-F, N,
S, T, X, Y]
Verify Not OK
PSWD not created
Verify Password
Otherwise, the "Exit Prog. Mode?" prompt is
displayed directly.
8
Exit Prog. Mode?
(Y/N)_
[Y], [N]
[ESC]
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the
Exiting Programming Mode
paragraph in this section.
9
Device Mode
(ECP)_
•
ECP
•
4204 Emu
•
Two 4204s
Press the [space] key to scroll through the
modes of operation. Press [ENTER] to select
ECP
mode.
IMPORTANT NOTE:
Do not select any other mode.
10
RIS Event Rpts
•
Disabled
•
4204 Sourced
•
2-4204
Sourced
•
Enhanced
Reports
Panel status events can be reported to the
end user via e-mail. To enable this feature,
press the [space] bar to scroll to the
“Enhanced Reports” option and press
[ENTER] to select the configuration. The
other options are available for legacy systems
only.
If not enabled, go to Prompt 16 "CS1 IP"
prompt.
11
RIS Event Addr
(12)
[01-30]
This address must be programmed if using
RIS Event Reporting. For the Lynx Plus and
ADT Safewatch QuickConnect 3000 panel,
the address must be 04.