Specifications & Accessories 

Security Control 

Physical: 12-1/2” W x 14-1/2” H x 3” D (318mm x 368mm x 76mm) 
Electrical: 

VOLTAGE INPUT: 16.5VAC from plug-in 25VA transformer, Ademco No. 1321 (1321CN in Canada) 

POWER SHUTDOWN NOTE:

 System shuts down sensor protection processing if control’s voltage drops below 9.6V. 

RECHARGEABLE BACKUP BATTERY: 12VDC, 17AH (sealed lead acid type). Charging Voltage: 13.8VDC. 
ALARM SOUNDER: 12V, 2.0 Amp output can drive 12V BELLS or can drive one or two 702 (series 

connected) self-contained 20-watt sirens. Do 

not 

connect two 702s in parallel. 

AUXILIARY POWER OUTPUT: 12VDC, 600mA max.  

 

UL installations

: Alarm Sounder plus Auxiliary Power currents should not exceed 600mA total. 

 

FUSE:  Battery (3A) No. 90–12 (PC board may have a PTC device instead of a fuse. The PTC serves as an 

automatically resetting fuse.) 

Communication:  

Ademco Contact ID Reporting: 10 characters/sec., DTMF (TouchTone) Data Tones, 1400/2300Hz ACK, 

1400Hz KISSOFF. 

LINE SEIZE: Double Pole 
FCC REGISTRATION No.: 5GBUSA-44003-AL-E 
RINGER EQUIVALENCE: 0.1B 

Maximum Zone Resistance: Zones 1–8 = 300 ohms excluding EOLR standard zones 

 

Compatible Devices 

Touchpads:

 

6150ADT, 6160ADT, 6160VADT; Touchpad Transceivers: 6150RFADT, 6160RF 

 

6270ADT Touch Screen Touchpad; iCenter Advanced User Interface 

RF Receivers: 

5881L/5882L:  accepts up to 8 transmitters

 

 

5881M/5882M: accepts up to 16 transmitters 

 

5881H/5882H: accepts up to system maximum transmitters 

 

5800TM Transmitter Module (used with wireless 2-Way devices) 

RF Transceivers: 

5883M (accepts up to 16 transmitters); 5883H (accepts up to system max. transmitters)

 

Zone Expansion:

 

4219 WIRED EXPANSION MODULE 

 

4229 WIRED EXPANSION/RELAY MODULE 

Relay Module:

 

4204 RELAY MODULE 

Phone Modules:

 

4286 PHONE MODULE 

Long Range Radio:

  7845GSMADT, 7845i-ent, GSMV-ADT 

2-Wire Smoke Detector: 

Detector Type

 

System Sensor 

Model No.

 

Photoelectric w/heat sensor 

2WT-B 

Photoelectric 

2W-B 

Photoelectric 

2151 w/B110LP base 

 

Transformers:

  1321: 16.5VAC, 25VA Plug-In Transformer (No. 1321CN in Canada) 

 

1361X10: 16.5VAC, 40VA Powerline Carrier Device Interface AC Transformer 

 

Sounders:

 

AB12M 10” Motorized Bell & Box 

749 Speaker/Horn 

 

1011BE12M 10” Motorized Bell & Box 

744 Siren Driver 

 

702 Outdoor Siren 

745X3 Voice Siren Driver 

 

719 2-Channel Siren 

705-820, 5-inch Round Speaker 

 

713 High Power Speaker 

713 Speaker 

 

746 Indoor Speaker 

WAVE Speaker 

 

747 Indoor Siren 

WAVE2 Two-Tone Siren 

 

747PD Two-Tone Piezo Dynamic Indoor Siren 

WAVE2PD Two-Tone Piezo Siren 

 

747UL Indoor Siren 

5800WAVE Wireless Siren 

 

748 Dual Tone Siren 

 

System Sensor  PA400B (beige)/; PA400R (red) Indoor Piezo Sounder 

Summary of Contents for Entrepreneur 3000EN

Page 1: ...and System Installation Notes For full installation and programming information please refer to the Installation and Setup Guide K5305V8 or higher ARMED READY 1 2 3 4 5 6 7 8 9 0 STAY BYPASS CHIME IN...

Page 2: ...ories 25 Recommendations for Proper Protection 27 FCC Industry Canada 27 UL Notices 28 Uploading Downloading via the Internet 29 The Limitations of This Alarm System 30 Summary of Connections 31 Atten...

Page 3: ...mming Press 80 4229 or 4204 Relay modules powerline carrier devices or on board triggers Zone List Programming Press 81 Zone Lists for relay powerline carrier activation chime zones pager zones etc Al...

Page 4: ...be 00 for UL Commercial Burg installations 29 Enable IP GSM Communication Device Menu Mode pass through programming This is a Menu Mode command not a data field for programming IP GSM communication de...

Page 5: ...Open Close Test 3 Alarms Restore Cancel All 4 All except Open Close Test All 5 All All 50 BURGLARY DIAL DELAY 2 0 Delay Time Delay Disable values other than those stated will give unpredictable result...

Page 6: ...ORE RPT CODE 1 Any non zero entry enables report 71 TROUBLE RESTORE RPT CODE 10 Any non zero entry in first digit enables report 72 BYPASS RESTORE RPT CODE 00 Any non zero entry in first digit enables...

Page 7: ...use zone list 7 to enter those zones that require unlimited reporting these zones ignore the setting in entry 1 DOWNLOAD INFORMATION 94 95 94 DOWNLOAD PHONE No Enter up to 20 digits 0 9 11 for 12 for...

Page 8: ...able 1 enabled 181 50 60 HERTZ AC OPERATION 0 0 60 Hz 1 50 Hz CONFIGURABLE ZONE TYPE OPTIONS 183 181 182 CONFIGURABLE ZONE TYPE 90 IMPORTANT Be careful when selecting combinations of options for confi...

Page 9: ...e Refer to the communication device s installation instructions for details on enabling the Remote Services feature TOUCHPAD OPTIONS 190 196 NOTE Options for touchpad 1 address 16 are set by the facto...

Page 10: ...6 Short dial delay fault delay ENTRY 7 ENTRY 8 Display Faults Power Reset Verification Use Entry Delay 1 2 Use Exit Delay Respond as Interior Type 0 show alarms when armed disarmed 1 don t show alarm...

Page 11: ...1 57 1 BR 1 58 1 BR 1 59 1 BR 1 60 1 BR 1 61 1 BR 1 62 1 BR 1 63 1 BR 1 64 1 BR 1 95 09 N A N A N A touchpad 1 96 N A N A N A touchpad 3 99 07 N A N A N A touchpad NOTES Zone Type see chart on page 12...

Page 12: ...10 MAPPING Must program before using 80 OUTPUT TYPE OUTPUT TYPE Relay X10 Relay X10 Output No Module Addr Pos 1 4 Unit No Description Output No Module Addr Pos 1 4 Unit No Description 01 09 02 10 03 1...

Page 13: ...or Zone Types are 00 Not Used 05 Trouble Day Alarm Night 10 Interior w Delay 24 Silent Burglary 01 Entry Exit 1 06 24 Hr Silent 12 Monitor Zone 25 24 Hr Non Alarm 02 Entry Exit 2 07 24 Hr Audible 14 C...

Page 14: ...07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Events Master Installer Installer Only 00 clear event 04 forced STAY arm 10 display custom words 8 10 01 device on off 05...

Page 15: ...has an emergency button Sends a report to the central station and provides an alarm sound at the touchpad and an audible external alarm Type 08 24 hour Auxiliary Alarm Assign to a zone containing an e...

Page 16: ...may not be used as fire or burglary zones in fire or UL burglar alarm installations The system can still be armed when these zone types are in a faulted condition Table of Device Addresses This Device...

Page 17: ...L 153 POWER R 155 RADIO 156 REAR 157 RECREATION 159 REFRIGERATION 160 RF 161 RIGHT 162 ROOM 163 ROOF S 164 SAFE 165 SCREEN 166 SENSOR 167 SERVICE 168 SHED 169 SHOCK 170 SHOP 171 SHORT 173 SIDE 174 SKY...

Page 18: ...that the board rests on the correct row see Detail A b Swing the base of the board into the mounting clips and secure the board to the cabinet with the accompanying screws see Detail B Notes Before in...

Page 19: ...resistance to damage from generally expected levels of lightning and electrical discharge and does not normally require an earth ground If an earth ground is desired for additional protection in area...

Page 20: ...For additional information regarding the 5800TM refer to the 5800TM s instructions Transmitters ULC Note for Canadian Units In accordance with ULC standards the RF supervision period for this control...

Page 21: ...ENROLL AS RF 5801 ENROLL AS UR OR RF 5800SS1 ENROLL AS RF LOOP 3 LOOP 1 LOOP 2 LOOP 4 YOU MUST ENROLL THIS BUTTON 5894PI ENROLL AS RF 5802 MN2 ENROLL AS UR OR RF LOOP 1 LOOP 1 LOOPS 1 3 LOOP 1 LOOP 1...

Page 22: ...keyswitch zone must be programmed to send opening and closing signals a UL commercial burglar alarm installation the keyswitch s tamper switch must be connected in to the alarm system This tamper swit...

Page 23: ...h aabout a twice per minute beeping at the touchpad indicates that a low battery condition exists in the wireless sensor displayed zone 00 indicates a wireless touchpad If the battery is not replaced...

Page 24: ...rn on and a LOW BATTERY report will be transmitted with a TEST report The touchpad will beep once about every 30 seconds as a reminder that the system is in the Test mode NOTE Wireless motion detector...

Page 25: ...es not confirm report transmissions 1 DIAL 0 WALK no special display on English Display Touchpads displays DISARMED READY TO ARM The following will be displayed accompanied by 2 beeps if test is succe...

Page 26: ...ers 6150RFADT 6160RF 6270ADT Touch Screen Touchpad iCenter Advanced User Interface RF Receivers 5881L 5882L accepts up to 8 transmitters 5881M 5882M accepts up to 16 transmitters 5881H 5882H accepts u...

Page 27: ...in any room where an alarm control is located or in any room where alarm control connections to an AC source or phone lines are made If detectors are not so located a fire within the room could preven...

Page 28: ...radation du service dans certaines situations Les r parations de mat riel nomologu doivent tre coordonn es par un repr sentant d sign par le fournisseur L entreprise de t l communications peut demande...

Page 29: ...nt 7845GSMADT System Requirements Internet Communication At the Installation Site Appropriate Internet Communication Module 7720P Programmer Broadband Internet Access for wired modules Broadband Cable...

Page 30: ...s closed doors glass partitions glass doors or windows Mechanical tampering masking painting or spraying of any material on the mirrors windows or any part of the optical system can reduce their detec...

Page 31: ...MINALS SEE INSTRUCTIONS REMOTE TOUCHPADS EACH PARTITION CAN USE 6150ADT OR 6160ADT TOUCHPADS SEE INSTRUCTIONS PROVIDED WITH TOUCHPAD LOCAL PROGRAMMING MUST BE DONE WITH A 6160ADT BUT NEED NOT REMAIN I...

Page 32: ...ORMATION For the latest warranty information please go to www honeywell com security hsc resources wa ADT Security Services Inc One Town Center Rd Boca Raton FL 33486 Copyright 2003 K9287V6 K9287V6 8...

Reviews: